Chapter 4
Connecting Signals
©
National Instruments Corporation
4-13
PFI6/WFTRIG
DIO
—
Vcc +0.5
3.5 at
(Vcc –0.4)
5 at 0.4
1.5
50 k
Ω
pu
PFI7/STARTSCAN
DIO
—
Vcc +0.5
3.5 at
(Vcc –0.4)
5 at 0.4
1.5
50 k
Ω
pu
PFI8/GPCTR0_SOURCE
DIO
—
Vcc +0.5
3.5 at
(Vcc –0.4)
5 at 0.4
1.5
50 k
Ω
pu
PFI9/GPCTR0_GATE
DIO
—
Vcc +0.5
3.5 at
(Vcc –0.4)
5 at 0.4
1.5
50 k
Ω
pu
GPCTR0_OUT
DO
—
—
3.5 at
(Vcc –0.4)
5 at 0.4
1.5
50 k
Ω
pu
FREQ_OUT
DO
—
—
3.5 at
(Vcc–0.4)
5 at 0.4
1.5
50 k
Ω
pu
AI = Analog Input
DIO = Digital Input/Output
pu = pull up
AO = Analog Output
DO = Digital Output
The tolerance on the 50 k
Ω
pull-up and pull-down resistors is very large. Actual value may range between 17 k
Ω
and 100 k
Ω
.
Table 4-6.
I/O Signal Summary for the AT-MIO-16XE-50
Signal Name
Drive
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mA at V)
Sink
(mA at V)
Rise
Time
(ns)
Bias
ACH<0..15>
AI
20 G
Ω
in
parallel with
100 pF
25/15
—
—
—
±3 nA
AISENSE
AI
20 G
Ω
in
parallel with
100 pF
25/15
—
—
—
±3 nA
AIGND
AO
—
—
—
—
—
—
DAC0OUT
AO
0.1
Ω
Short-circuit
to ground
5 at 10
5 at –10
2
V/µs
—
DAC1OUT
AO
0.1
Ω
Short-circuit
to ground
5 at 10
5 at –10
2
V/µs
—
AOGND
AO
—
—
—
—
—
—
DGND
DO
—
—
—
—
—
—
Table 4-5.
I/O Signal Summary for the AT-MIO-16XE-10 and AT-AI-16XE-10 (Continued)
Signal Name
Drive
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mA at V)
Sink
(mA at V)
Rise
Time
(ns)
Bias