Output Characteristics

Digital Output Logic Levels at 8 mA loads

High .................................................................. 4.0 V to 5.0 V

Low................................................................... 0.1 V to 0.4 V

Input Characteristics

Differential Input Logic Levels

High .................................................................. (a - b) > 200 mV

Low................................................................... (a - b) < -200 mV

Physical Specifications and Characteristics

Weight............................................................... 170 g

Maximum Altitude ........................................... 2000 m

Maximum Ambient Temperature ..................... 70 ºC

Operating Humidity.......................................... 10% to 90% RH, noncondensing

Pollution Degree ............................................... 2 

Ingress Protection ............................................. IP40

For indoor use only.

If you need to clean the module, wipe it with a dry towel.

Safety Guidelines

Caution

Do not operate the NI 9753 in a manner not specified in these operating 

instructions. Product misuse can result in a hazard. You can compromise the safety 
protection built into the product if the product is damaged in any way. If the product 
is damaged, return it to National Instruments for repair.

Summary of Contents for 9753

Page 1: ...igital I O Module Contents Introduction 2 Pinout 2 Hardware 3 Powering the Module 3 Platform Compatibility 4 Inputs and Outputs 5 Compliance and Certifications 5 Output Characteristics 7 Input Charact...

Page 2: ...iving fuel injectors or ignition coils The outputs can be used for commands to external custom driver circuits or smart actuators with built in driver circuits Multiple fuel and spark VIs can be wired...

Page 3: ...other device The other power connection is at the external DB 37 connector labeled BATT 19 and GND 18 Typical power sources will be from automotive 12 V or 24 V battery systems The NI 9753 can accept...

Page 4: ...ontrol modules are not compatible with the National Instruments CompactDAQ chassis You can use NI Powertrain Control modules with NI cRIO 911x NI cRIO 907x and NI R Series Expansion systems under the...

Page 5: ...2V Compliance and Certifications Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 6101...

Page 6: ...products must be sent to a WEEE recycling center For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Ele...

Page 7: ...imum Ambient Temperature 70 C Operating Humidity 10 to 90 RH noncondensing Pollution Degree 2 Ingress Protection IP40 For indoor use only If you need to clean the module wipe it with a dry towel Safet...

Page 8: ...ruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents You can find...