Getting Started with NI 9512 and P7000 Drives
|
© National Instruments
|
21
Note
National Instruments recommends using insulated wire ferrules to prevent
shorting and add strain relief.
Step 6: Configure the P7000 Drive with the Serial Port
(Optional)
Note
This step is required only if you are using the P7000 Tools configuration
software and configuring the drive with the RS-232 port. If you are using an NI
stepper motor, you can configure the drive with the DIP switches only and proceed
to
Step 3: Install Software on and Configure the NI RT Controller
Configuration and Installation
section to configure the RT target.
1.
Connect the RS-232 serial communication cable between the drive and an available COM
port on the computer.
You must set the COM port to the following settings:
•
Baud Rate:
19,200
•
Data Bits:
8
•
Parity:
Even
•
Stop Bits:
1
•
Flow Control:
None
Table 13.
J7 DC Power
Pin
Description
J7–1 (+Bus)
Plus power supply terminal
20 to 75 V
5 A max
Isolated power supply
J7–2
(Gnd)
Negative power supply terminal
Negative power supply terminal/Bus
Gnd is normally earthed
Maximum allowable voltage
between Bus Gnd (J7–2) and Chassis
(J7–3) is 100 V peak
J7–3
(PE)
Connect to PE (Protective Earth)
J7–3 connects to J6–5 inside drive (shield)