nash_elmo Industries GmbH
11 / 23
Order No.: 610.44436.40.000
Subject to change
Edition 09/2003
Installation
For
transport with a crane
, the pump-motor
unit can be hooked onto the crane hook as
follows:
•
directly on the eye bolt
or possibly
•
with lifting belts.
Eye bolt:
All models are equipped with an eye bolt. The
eye bolt is mounted on the vacuum
pump/compressor housing.
In case of possible removal and remounting of
the eye bolt, it must be ensured that the eye
level is positioned exactly in the axis direction
of the pump-motor unit. Lay shims under the
eye bolt if necessary.
The eye bolt must be firmly tightened.
Loads laterally to the ring level are not
permissible. Heavy impact loads during
transport must be avoided.
5 Installation
WARNING
Improper use of the unit can result in
serious or even fatal injuries!
Have you read the safety precautions in
Chapter 1, "Safety", Pg. 3 f.?
Otherwise you many not carry out any work
with or on the pump-motor unit!
DANGER
Danger from missing view into area of
pump-motor unit!
When operating the control elements without a
view into the area of the pump-motor unit,
there is a danger that the pump-motor unit will
be switched on while other persons are still
performing work on it. Extreme injuries are
possible!
Provide control elements at a location with a
view of the pump-motor unit.
DANGER
Electrical danger!
The pump-motor unit must be installed so that
the electrical device cannot be damaged by
external influences!
In particular, the feed pipes must be securely
routed, e.g. in cable ducts, in the floor etc.
WARNING
Danger from balance damage caused by
vibration!
Vibrating environments can cause balance
damage!
Install the pump-motor unit on a solid
foundation or on a solid mounting surface.
Check screw glands/unions for mounting the
pump-motor unit on the mounting surface
regularly for strength and firm seating.
WARNING
Danger from crushing due to pump-motor
unit tipping over!
Wear personal safety equipment (protective
gloves and safety shoes).
Handle the unit with the appropriate care.
Install the pump-motor unit on a solid
foundation or on a solid mounting surface!
Check screw glands/unions for mounting the
pump-motor unit on the mounting surface
regularly for strength.
WARNING
Danger of fire from flammable substances!
The pump-motor unit must never come into
contact with flammable substances.
For exact information on the temperature
increase, see Chapter 3.1, "Mechanical data",
Section "Temperature increase", Pg. 8.
WARNING
Danger of burns from hot surfaces of the
pump-motor unit and from hot fluids!
High temperatures of up to approx. 160 °C
[320 °F] can occur on the surface of the pump-
motor unit.
The pump-motor unit must be installed so that
accidental touch of its surface is not possible.
Cover the pump-motor unit with a suitable
touch protection (e.g. perforated plate cover or
wire cover).
WARNING
Danger of injuries from flying parts!
Select installation so that parts that are thrown
out through the grate if the external fan breaks
cannot hit persons!