7 Direction Finding Mode
142
IDA
-
3106
Narda
7.6
Exchanging bearings between
instruments
Direction Finding • External Bearing
You will normally only use one IDA
-
3106 and will therefore have to move to
a different location to take bearings from different points. If more than one
instrument is available, you can have measurements made at several
locations simultaneously and exchange the results or transfer them to one
IDA
-
3106 for evaluation.
The bearing results from the other instruments can be read over a radio or
mobile phone link and entered manually, for example.
To use bearing results from other instruments:
A localization must be open, otherwise transfer can only be made as a
single data set.
1.
Press the
External Bearing
softkey.
The menu for entering the measured values opens and initially shows
the current bearing results for the instrument itself.
2.
Select the items using the rotary control knob, press
OK
to open them,
enter the values as measured, and press
OK
to confirm:
–
Fcent:
center frequency
–
Transmitter
: Transmitter name
(optionally, you can make the selection from a transmitter in the loaded
transmitter table. Fcent is then entered automatically)
–
Value:
Data is exchanged in dBµV/m for field strength, otherwise in
dBµV
–
Latitude:
Measurement location latitude (in DegDec)
–
Longitude:
Measurement location longitude (in DegDec)
–
Azimuth:
measured azimuth value, 0° (North) to 359.9°
3.
After you have entered all the values, press the
Save External Bearing
softkey to save the bearing in the open localization.
This bearing is now part of the localization just like the bearings taken
using your own instrument.
NOTE:
Items 1 and 2 are used as well for transferring to other instruments. This
ensures that the transfer is made in suitable units.
Summary of Contents for IDA
Page 1: ...IDA 3106 Interference and Direction Analyzer Operating Manual IDA IDA 2...
Page 8: ...Contents VI IDA 3106 Narda...
Page 28: ...2 Important Safety Instructions 20 IDA 3106 Narda...
Page 134: ...6 Common Functions 126 IDA 3106 Narda...
Page 166: ...7 Direction Finding Mode 158 IDA 3106 Narda...
Page 188: ...9 Level Meter Mode 180 IDA 3106 Narda...
Page 206: ...10 Time Domain Scope Mode 198 IDA 3106 Narda...
Page 218: ...11 I Q Analyzer Mode 210 IDA 3106 Narda...
Page 238: ...13 Measurement Data Memory 230 IDA 3106 Narda...
Page 242: ...14 Maintenance Repairs Updates 234 IDA 3106 Narda...
Page 246: ...15 PC Software 238 IDA 3106 Narda...
Page 254: ...16 Remote Control 246 IDA 3106 Narda...
Page 269: ...17 4 Antenna handle and antennas Narda IDA 3106 261 17 4 7 Antenna factors typical...
Page 272: ...17 Specifications 264 IDA 3106 Narda...
Page 284: ...19 Glossary 276 IDA 3106 Narda...
Page 290: ...Index 282 IDA 3106 Narda...
Page 291: ......