Narda
IDA
-
3106
125
6.16
Changing the operating mode
There are two ways to change the operating mode:
• Using the same parameters by means of the
Extras
softkey
• Without using the same parameters by means of the Main menu
6.16.1 Changing the operating mode and keeping the
same parameters
You can switch directly from one operating mode to another without opening
the main menu. Certain measurement parameters are kept the same when
you do this, depending on the target operating mode (see table below).
To change the operating mode keeping the same parameters:
1.
Press the
Extras
softkey.
2.
Press the
Go to: ...
softkey for the desired operating mode.
NOTE:
The RBW values set in the multi-channel tables have no function when
parameters are retained. These RBW values are only used in
Multi
-
Channel Power mode. If a channel is marked in Multi
-
Channel Power
mode, the parameters are kept for this channel bandwidth when the
operating mode is changed, and the most suitable CBW is set.
6.16.2 Changing the operating mode from the Main
menu
1.
Press the
MENU
key until the Main menu is displayed.
2.
Press the softkey for the desired operating mode.
Table 30: Parameters retained when changing operating mode
Parameter
Operating modes
Fcent
All operating modes
Marker frequency
Instead of Fcent when marker is activated in
Spectrum
, and for the frequency views in
I⁄Q Analyzer
CBW
In
Direction Finding, Time Domain (Scope)
,
Level Meter
and
I⁄Q Analyzer
Demodulation bandwidth
set as CBW
From
Spectrum
to
Direction Finding
,
Level Meter
,
Time Domain (Scope)
and
I⁄Q Analyzer
Summary of Contents for IDA
Page 1: ...IDA 3106 Interference and Direction Analyzer Operating Manual IDA IDA 2...
Page 8: ...Contents VI IDA 3106 Narda...
Page 28: ...2 Important Safety Instructions 20 IDA 3106 Narda...
Page 134: ...6 Common Functions 126 IDA 3106 Narda...
Page 166: ...7 Direction Finding Mode 158 IDA 3106 Narda...
Page 188: ...9 Level Meter Mode 180 IDA 3106 Narda...
Page 206: ...10 Time Domain Scope Mode 198 IDA 3106 Narda...
Page 218: ...11 I Q Analyzer Mode 210 IDA 3106 Narda...
Page 238: ...13 Measurement Data Memory 230 IDA 3106 Narda...
Page 242: ...14 Maintenance Repairs Updates 234 IDA 3106 Narda...
Page 246: ...15 PC Software 238 IDA 3106 Narda...
Page 254: ...16 Remote Control 246 IDA 3106 Narda...
Page 269: ...17 4 Antenna handle and antennas Narda IDA 3106 261 17 4 7 Antenna factors typical...
Page 272: ...17 Specifications 264 IDA 3106 Narda...
Page 284: ...19 Glossary 276 IDA 3106 Narda...
Page 290: ...Index 282 IDA 3106 Narda...
Page 291: ......