Napoleon GDS60-N Installation And Operating Instrictions Download Page 4

4

W415-0788 / 05.15.09

 NAPOLEON® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not 
necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON® 
reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim. Provided that the 
purchase was made through an authorized NAPOLEON® dealer your heater is subject to the following conditions and limitations:
  This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
  The gas heater must be installed by a licensed, authorized service technician or contractor. Installation must be done in accordance 
with the installation instructions included with the product and all local and national building and fi re codes.   This limited warranty does 
not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other 
manufacturers will nullify this warranty.
  This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and 
chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers.
  NAPOLEON® warrants its stainless steel burners against defects in workmanship and material for life, subject to the following 
conditions: During the fi rst 10 years NAPOLEON® will replace or repair the defective parts at our option free of charge. From 10 years 
to life, NAPOLEON® will provide replacement burners at 50% of the current retail price.
  In the fi rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or 
workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
  After the fi rst year, with respect to this President’s Lifetime Limited Warranty, NAPOLEON® may, at its discretion, fully discharge all 
obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but 
defective part(s).
  NAPOLEON® will not be responsible for installation, labour or any other expenses related to the reinstallation of a warranted part and 
such expenses are not covered by this warranty.
  Notwithstanding any provisions contained in the President’s Lifetime Limited Warranty, NAPOLEON’S responsibility under this 
warranty is defi ned as above and it shall not in any event extend to any incidental, consequential or indirect damages.
  This warranty defi nes the obligations and liability of NAPOLEON® with respect to the NAPOLEON® gas heater and any other 
warranties expressed or implied with respect to this product, its components or accessories are excluded.
  NAPOLEON® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of 
this product. 
  NAPOLEON® will not be responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, 
buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or 
negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  Any damages to heater, combustion chamber, heat exchanger, brass trim or other components due to water, weather damage, long 
periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON®.

2.1

NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 

Quality Assurance Certifi cate.

NAPOLEON® products are designed with superior components and materials assembled by trained 

craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a 

quality test station. The complete heater is again thoroughly inspected by a qualifi ed technician before 

packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON®.

The following materials and workmanship in your new NAPOLEON® gas heater are warranted against 
defects for as long as you own the heater. This covers: combustion chamber, heat exchanger, stainless 
steel burner, phazer™ logs and embers, rocks, ceramic glass (thermal breakage only), gold plated parts 
against tarnishing, porcelainized enameled components and aluminum extrusion trims.*
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, 
switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and NAPOLEON® will 
provide replacement parts free of charge during the fi rst year of the limited warranty.*
Labour related to warranty repair is covered free of charge during the fi rst year. Repair work, however, 
requires the prior approval of an authorized company offi cial. Labour costs to the account of NAPOLEON® 
are based on a predetermined rate schedule and any repair work must be done through an authorized 
NAPOLEON® dealer.
* Construction of models vary. Warranty applies only to components included with your specifi c heater.

NAPOLEON® GAS FIREPLACE PRESIDENT’S LIFETIME LIMITED WARRANTY

CONDITIONS AND LIMITATIONS

ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT 

IMPROVEMENTS.  NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD.  PATENTS U.S. 5.303.693.801 - CAN. 

2.073.411, 2.082.915. © WOLF STEEL LTD.

1.1 WARRANTY

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Summary of Contents for GDS60-N

Page 1: ...liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediate...

Page 2: ...2 3 HORIZONTAL AIR TERMINAL INSTALLATION MODEL GDS60 26 4 2 4 VERTICAL AIR TERMINAL INSTALLATION MODEL GDS60 27 4 3 APPLIANCE VENT CONNECTION MODEL GDS60 28 4 4 MOBILE HOME INSTALLATION MODEL GDS60 28...

Page 3: ...its venting system should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc...

Page 4: ...N gas heater and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither assumes nor authorizes any third party to assume on...

Page 5: ...CTS PLACED IN FRONT OF THE FIREPLACE MUST BE KEPT A MINIMUM 48 FROM THE FRONT FACE OF THE UNIT THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH...

Page 6: ...nel extending the full width and depth We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Appliance Institute NFI as NFI Ga...

Page 7: ...ency of 78 Maximum output for propane is 24 570 BTU hr at an efficiency of 78 Maximum A F U E Annual Fuel Utilization Efficiency rating is 72 for natural gas and 71 for propane REAR VENT HORIZONTAL TE...

Page 8: ...ze after ignition Vent lengths that pass through unheated spaces attics garages crawl spaces should be insulated with the insulation wrapped in a protective sleeve to minimize condensation Provide a m...

Page 9: ...cluded or 1 12 to 7 12 pitch roof terminal kit GD110 8 12 to 12 12 roof terminal kit GD111 flat roof terminal kit GD112 or periscope kit GD180 for wall penetration below grade in conjunction with the...

Page 10: ...5 09 2 2 TYPICAL VENT INSTALLATIONS 30 1 2 TOP VENT REAR VENT 16 MINIMUM 40 FEET MAXIMUM 34 MINIMUM 16 MINIMUM 40 FEET MAXIMUM 34 MINIMUM 24 NorthlineExpress com http www northlineexpress com Toll Fre...

Page 11: ...ADE 24 MINIMUM REGARDLESS OF HORIZONTAL VENT LENGTH MAX HORIZONTAL RUN 34 MAXIMUM 29 MINIMUM 30 1 2 59 1 2 MINIMUM PLUS RISE 24 MAX 24 MINIMUM PLUS RISE See VENTING section NorthlineExpress com http w...

Page 12: ...is located a minimum 12 above grade The maximum allowable vent length is 10 9 4 24 MAXIMUM 0 RISE CORNER INSTALLATION 2 4 CORNER INSTALLATION REAR EXIT 2 3 SPECIAL VENT INSTALLATIONS 29 MINIMUM 12 MI...

Page 13: ...Clearance to a mechanical air supply inlet L 7 7 Clearance above a paved sidewalk or paved driveway located on public property M 12 12 Clearance under a veranda porch deck or balcony N 16 16 Clearanc...

Page 14: ...the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 13 2 REAR EXIT Horizontal Termination Vertical Termination Vertical rise is equal to or greater than the horiz...

Page 15: ...l of both horizontal vent lengths Hr and offsets Ho in feet HR combined horizontal vent lengths in feet HO offset factor 03 total degrees of offset 90 in feet VT combined vertical vent lengths in feet...

Page 16: ...la 1 HT 4 2 VT 4 2 VT 4 2 x 6 25 2 FT Formula 2 HT VT 24 75 FT 16 7 24 75 Since both formulas are met this vent configuration is acceptable 0 5 15 20 100 50 150 12 5 19 1 2 57 147 2 The shaded area wi...

Page 17: ...re than one 90 elbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 1 V1 3 FT V2 8 FT VT V1 V2 3 8 11 FT H1 2 5 FT H2 2 FT HR H1 H2 2 5 2 4 5 FT HO 03 three 90 elbows 90...

Page 18: ...mula 1 HT VT 14 6 15 Formula 2 HT VT 40 FT 29 6 40 Since both formulas are met this vent configuration is acceptable 0 2 5 5 7 5 10 12 5 15 40 10 20 30 17 5 20 1 6 1 6 38 3 90 V1 V2 H1 H2 90 90 90 H3...

Page 19: ...5 5 5 FT H1 2 FT H2 1 FT H3 1 FT H4 1 5 FT HR H1 H2 H3 H4 2 1 1 1 5 5 5 FT HO 03 four 90 elbows one 45 elbow 90 03 90 90 90 90 45 90 9 45 FT HT HR HO 5 5 9 45 14 95 FT HT VT 14 95 5 5 20 45 FT Formul...

Page 20: ...apply Formula 1 HT VT Formula 2 HT VT 40 feet Example 6 V1 5 FT V2 6 FT V3 10 FT VT V1 V2 V3 5 6 10 21 FT H1 8 FT H2 2 5 FT HR H1 H2 8 2 5 10 5 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 10...

Page 21: ...FT HR H1 H2 6 2 8 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 8 8 1 16 1 FT HT VT 16 1 4 5 20 6 FT Formula 1 HT 3 5 VT 3 5 VT 3 x 4 5 13 5 FT 16 1 13 5 Since this formula is not met this ven...

Page 22: ...18 2_3 3 1 ORIFICE REPLACEMENT REAR VENT TERMINATION In rear exit installations with no vertical vent run the BTU input must be reduced to 21 000 BTU by changing the orifice In order to access the ori...

Page 23: ...lustrated When reinstalling in the alternate position Check gaskets for tears replace if necessary to ensure a proper seal 4 Gasket 7 Cover Plate 7 Gasket 4 Gasket 4 Collar 7 Gasket 7 Collar Outer Top...

Page 24: ...LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO MAINTAIN CLEARANCES TO COMBUSTIBLES 4 1 MINIMUM CLEARANCE TO COMBUSTIBL...

Page 25: ...hat are less than 8 1 2 thick but the vent shield must extend the full depth of the combustible wall A Apply a bead of caulking not supplied around the corner edge of the inside surface of the firesto...

Page 26: ...vailable from your authorized dealer distributor See accessories to order specific kits required A Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and...

Page 27: ...terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly centred within the fl...

Page 28: ...done by a qualified installer Do not use open flame Move the appliance into position and secure If equipped with a flex connector the appliance is designed to accept a 1 2 gas supply Without the conn...

Page 29: ...SE D AIR CERTIFIED UNDER CSA 2 33 2000 ANSI Z21 88 2000 VENTED GAS FIREPLACE HEATER AS A DIRECT VENT AND CSA2 22 M98 ANSI Z21 50 1998 VENTED GAS FIREPLACE AS A B VENT HOMOLOGUE SELON LES NORMES CSA 2...

Page 30: ...into the appliance flue collar F Connect the upper wire terminals to the spill switch G Disconnect the wire lead from terminal 3 on the valve and re connect to the male end of the spill switch wire C...

Page 31: ...the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles Ensure that the vent pipe is properly centered within the flashing giving a 3 4 margin all around Faste...

Page 32: ...ove the backing of the logo supplied and centre over the logo installation holes as indicated 5 2 SWITCH AND BRACKET INSTALLATION 1 3 CONNECT THE TWO WIRES TO THE SWITCH TERMINALS 2 NorthlineExpress c...

Page 33: ...ts retainers located at either side on the top 5 4 3 Open the valve control cover Pull the latch handles forward to release The door may now be safely removed by swinging the bottom out and lifting it...

Page 34: ...end of the grate as shown to prevent it from rocking 6 7 Position the notch located in log 6 against the grate post Place the bottom of log 7 against the right outermost grate post and the top into t...

Page 35: ...turn the unit off and check for vent blockage or restriction If necessary consult with a qualified inspector 6 1 OPERATING INSTRUCTIONS The on off switch is located on the back of the unit at the top...

Page 36: ...UIPPED WITH AN IGNITION DEVICE WHICH AUTOMATI CALLY LIGHTS THE PILOT DO NOT TRY TO LIGHT BY HAND B BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE SOME GAS I...

Page 37: ...CPI IPI MODE DC BACK UP SUPPLY NOT USED STABALIZED SUPPLY OUTLET GROUND DFC VALVE ORANGE GREEN GROUND EYELET ON OFF IPI CPI DISCONNECT AND INSTALL LEADS TO MILLIVOLT THERMOSTAT NorthlineExpress com h...

Page 38: ...proximately 30 45 minutes after the appliance has been turned off Use of the fan increases the output of heat Drywall dust will penetrate into blower bear ings causing irreparable damage and must be p...

Page 39: ...o disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance and its venting system should be inspected befor...

Page 40: ...nal injury WARNING COMMON COMPONENTS REF NO PART NO DESCRIPTION 1 W135 0209 LOG 1 2 W135 0082 CHARCOAL PIECE LOG 2 3 W135 0076 LOG 3 4 W135 0210 LOG 4 5 W135 0211 LOG 5 6 W135 0212 LOG 6 7 W135 0213 L...

Page 41: ...CK BAND 45 GD180 PERISCOPE TERMINAL KIT 35 BM6790 90 ELBOW 7 DIAMETER 37 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 38 W010 1313 FIRESTOP SPACER 39 W585 0267 TOP VENT SHIELD 40 W020 0032 HARDWARE 41 BM373...

Page 42: ...301 HEAT GUARD 62 W175 0001 4 COUPLER 46 GD 201 PERISCOPE 63 GDSRP KT RESTRICTOR KIT 64 GS 150KT ADAPTOR KIT 65 W025 0003 DECORATIVE BLACK BAND ROOF TERMINAL KITS REF NO PART NO DESCRIPTION GD110 1 1...

Page 43: ...0788 05 15 09 47 50 49 48 61 46 24 37 42 38 44 35 25 27 10 1 2 3 4 5 7 6 29 33 32 44 28 26 55 9 20 11 57 61 36 8 41 44 44 51 13 12 NorthlineExpress com http www northlineexpress com Toll Free 1 866 6...

Page 44: ...assemblies are properly grounded to the metal chassis of the fireplace or log set Faulty module Turn the ON OFF switch to the OFF position Remove the igniter wire I from the module Place the ON OFF s...

Page 45: ...all wiring is installed exactly as specified Wiring harness Inspect the wiring harness and verify the harness is tightly connected to the module Verify that you have 7 wires and they are connected in...

Page 46: ...Y Appliance Service History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name 43 1 NorthlineExpress com http www nort...

Page 47: ...47 W415 0788 05 15 09 14 0 NOTES 44 1 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 48: ...48 W415 0788 05 15 09 44 1 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...