background image

2

W415-0682 / D / 02.06.12

TABLE OF CONTENTS

1.0 VENTING 

2

1.1 INSTALLATION 

OVERVIEW 

3

1.2 VENT 

TERMINAL 

CLEARANCES 

4

1.3 VENT 

LENGTHS 

5

1.4 POWER 

VENT 

TERMINAL 

5

1.4.1 TERMINAL 

INSTALLATION 

5

1.4.2 

POWER VENT INSTALLATION 

6

1.4.3 

INITIAL FIRING PROCEDURES 

6

1.4.4 ELECTRICAL 

CONNECTION 

7

1.4.5 

HARD WIRING CONNECTION 

7

1.4.6 

RECEPTACLE WIRING DIAGRAM 

7

1.4.7 

ELECTRICAL BOX INSTALLATION 

8

1.5 

RESTRICTOR PLATE INSTALLATION 

9

1.6 

WIRING DIAGRAM AND INSTALLATION 

9

1.6.1 

SIT IPI 885 PROFLAME COMPLETE WITH GPV POWER VENT TERMINAL 

9

1.6.2 

SIT MILLIVOLT 820 NOVA COMPLETE WITH GPV POWER VENT TERMINAL 

11

1.6.3 

SIT IPI 880/886 PROFLAME COMPLETE WITH GPV POWER VENT TERMINAL 

12

1.6.4 

DEXEN IPI 6003-3V COMPLETE WITH GPV POWER VENT TERMINAL 

13

1.6.5 

SIT REMOTE CONTROLLED MILLIVOLT SYSTEM COMPLETE WITH GPV POWER VENT TERMINAL 

14

2.0 ADJUSTMENTS 

15

2.1 VENTURI 

ADJUSTMENTS 

15

3.0 REPLACEMENTS 

15

4.0 TROUBLESHOOTING 

16

NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.

1.0 VENTING

There are speci

fi

 c adaptors and venting requirements for each appliance, refer to your power vent adaptor 

lea

fl

 et for more information.  

For complete installation instructions refer to the following web sites: 

Manufacturer

Website

Napoleon - English

http://www.napoleon

fi

 replaces.com/Tech/installation_manuals/installations.html

Napoleon - French

http://www.napoleonfoyers.com/Fireplaces/powervent.html

Continental

http://www.continental

fi

 replaces.com/

fi

 replaces/gas/powervent.html

Summary of Contents for GAS POWER VENT

Page 1: ...LIANCE When selecting a gas appliance for use with the GPV take into consideration the various requirements and limitations in the venting installation section for the following models Models Equipped...

Page 2: ...TE WITH GPV POWER VENT TERMINAL 12 1 6 4 DEXEN IPI 6003 3V COMPLETE WITH GPV POWER VENT TERMINAL 13 1 6 5 SIT REMOTE CONTROLLED MILLIVOLT SYSTEM COMPLETE WITH GPV POWER VENT TERMINAL 14 2 0 ADJUSTMENT...

Page 3: ...A typical vent configuration Reducer refer to power vent adapter kit PVA for specific vent ing instructions where applicable Gas Power Vent Terminal Electrical Box velcro to base LHD50 Illustrated Fir...

Page 4: ...rance under a veranda porch or deck N 12 12 Clearance above the roof O 2 2 Clearance from an adjacent wall including neighbouring buildings P 8 8 Roof must be non combustible without openings Q 3 3 Se...

Page 5: ...onnections must conform with local codes or in the absence of local codes use the current CSA C22 1 Canadian Electrical Code in Canada or the ANSI NFPA 70 National Electrical Code in the United States...

Page 6: ...ge F If more vent pipe needs to be used to reach the appliance couple them together as illustrated The vent system must be supported approximately every 3 feet for both vertical and horizontal runs Us...

Page 7: ...0 IN THE UNITED STATES ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE GLASS DOOR OPENED OR REMOVED 69 2 It is necessary to hard wire this appliance Permane...

Page 8: ...f the appliance and connect the box connector to the side panel see INSTALLATION OVERVIEW section for illustration D Feed the wires through the inside panel slide the split bushing over the coated wir...

Page 9: ...al codes use the current CSA C22 1 Canadian Electrical Code in Canada or the ANSI NFPA 70 National Electrical Code in the United States REFER TO PVA KIT FOR APPLIANCE SPECIFIC INSTRUCTIONS 1 6 1 SIT I...

Page 10: ...OW MOTOR BLACK MOTOR BROWN MOTOR WHITE Receiver Control Module POWER Pilot Assembly GREEN ON OFF BLACK RED IMPORTANT IF USED IT MUST BE CONNECTED TO A 6 VOLT BATTERY PACK HOWEVER MUST NOT BE USED WHEN...

Page 11: ...Terminal Power Vent Control Module Appliance Junction Box JUMPER 2 1 NOTE Must use double pole switch supplied or double pole thermostat not supplied with specific power vent adaptor kit NOTE Downward...

Page 12: ...pliance Junction Box BLACK WHITE YELLOW YELLOW BLOWER VAC SWITCH GREEN GPV Terminal Double Pole Switch YELLOW YELLOW JUMPER 2 1 IMPORTANT A receptacle may need to be installed as a power source for th...

Page 13: ...m the Power vent control module Dexen Gas Valve Ignition Module Battery Holder Battery Relay ORANGE YELLOW GREEN BLACK ORANGE BLUE RED BROWN BROWN BLUE BLACK YELLOW YELLOW BLACK WHITE ORANGE RED GREEN...

Page 14: ...itch supplied or double pole thermostat not supplied with specific power vent adaptor kits NOTE Downward venting is not allowed with appliances that use standing pilots 1 Disconnect one of the two wir...

Page 15: ...art Finish IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR AUTHORIZED DEALER 41 1 FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PA...

Page 16: ...chamber surfaces Clean the glass with a gas appliance glass cleaner DO NOT CLEAN GLASS WHEN HOT If deposits are not cleaned off regularly the glass may become permanently marked Exhaust fumes smelled...

Reviews: