NAPCO StarLink SLE-LTEVI Series Installation Instructions Manual Download Page 14

14 

StarLink

 SLE Commercial LTEVI & LTEAI Series Dual-Path Alarm Communicators -- Installation Instructions

 

WIRING THE TAMPER SWITCHES  

Before installation and wiring, the tamper switches (part 

GEM-

Tamperkit

) are normally open devices; when placed into 

the circuit and into operation, they are normally closed devic-

es.   

 

Tamper switches protect against the opening of the radio cabi-

net door or the removal of the radio enclosure from the wall or 

other mounting surface.   

 

There are two places in the cabinet to mount tamper switches: 

(1) To prevent cabinet removal from the wall, located on the 

left side of the cabinet there is one knockout for the switch 

plunger and three mounting holes (in the enclosure sheet met-

al).  (2) To protect the cabinet door,  mount a tamper switch in 

the three mounting holes (in the enclosure sheet metal).  

When mounted, the switch button contacts the inside surface 

of the door.  

Note:  

Be sure to alert the user that opening the 

enclosure door will cause a tamper alarm.   

 

Wiring a normally closed sensor loop for tamper supervision, 

wire to a zone on the control panel. 

GEM-Tamperkit 

consists of 

Description 

QTY 

SC206LF 

Slotted Pan Head 6-32 x 3/4 

Machine Screw 

SW105 

Tamper Switch 

Tamper Switch Mounting Instructions 

Back T

am

per 

D

o

or

 Tam

p

er

 

VIEW OF TAMPER SWITCHES: 

(1) = ENCLOSURE BASE;  

(2-BACK) = TAMPER SWITCH TO PREVENT REMOVAL FROM WALL;  

(3-DOOR) = TAMPER SWITCH TO PROTECT THE ENCLOSURE 

DOOR 

Name 

Format Type 

Handshake Frequency 

Speed 

Ademco Slow 

4/2 

1400 Hz or 2300Hz 

10pps 

Ademco Slow 

4/2 checksum 

1400 Hz or 2300Hz 

10pps 

Radionics Slow 

4/2 

2300Hz 

10pps 

Radionics Slow 

4/2 checksum 

2300Hz 

10pps 

Silent Knight Fast 

4/2 

1400 Hz or 2300Hz 

20pps 

Silent Knight Fast 

4/2 checksum 

1400 Hz or 2300Hz 

20pps 

Radionics Fast 

4/2 

2300Hz 

40pps 

Radionics Fast 

4/2 checksum 

2300Hz 

40pps 

Universal High Speed 

4/2 

1400 Hz or 2300Hz 

40pps 

Universal High Speed 

4/2 checksum 

1400 Hz or 2300Hz 

40pps 

4/2 Pulse Dialing 

Format  

Compatibility 

Note:

  T

h

e SL

E Du

al

-Path Series R

adi

os 

are comp

atibl

e

 w

ith 

an

y Liste

d 4/2 

Receiv

er such 

as the Ademc

o

 685.

 

Summary of Contents for StarLink SLE-LTEVI Series

Page 1: ...ential Fire alarm capture radio IP communicators are fully supervised wireless digital two way subscriber units All models are compatible with most 12 24VDC alarm control panels always adhere to the d...

Page 2: ...Smart Channel input Active high input for wiring to the control panel bell output When this input detects a pulsing temporal 3 high it sends a Fire alarm a pulsing temporal 4 CO Alarm a CO alarm is se...

Page 3: ...or wet contacts TB22 N O OUT2 Normally open Dry contact Form C relay TB23 C OUT2 Common Dry contact Form C relay Relay rated 30V AC DC 500mA TB24 N C OUT2 Normally closed Dry contact Form C relay LED...

Page 4: ...ded on the premises then only 4 hours of UPS backup are required JUMPER DESCRIPTIONS Jumper block labeled X5 from top to bottom as detailed in the table below Note Contact ID is always available in re...

Page 5: ...s STEP 2 SELECT A MOUNTING LOCATION The mounting location should be indoors within the protect ed area and selected based on RF performance It is HIGHLY recommended that the installer carefully adhere...

Page 6: ...ly trouble output relay to the two terminals of the control panel zone dedicated to the trouble With the GEMC Commercial Fire control panels use the dry contacts of the Power Supply relay by removing...

Page 7: ...apcoNOC com to enable Tip Ring Wiring Fault Report Refer to wiring diagram Supervision Time Schedule Considerations If a status change alarm trouble etc is transmitted the radio supervision timer is r...

Page 8: ...8 StarLink SLE Commercial LTEVI LTEAI Series Dual Path Alarm Communicators Installation Instructions This page intentionally left blank...

Page 9: ...ition maintain a minimum 1 4 separation of all primary wiring in the transformer compartment from the yellow secondary wires of the transformer Remove shunt J2 to isolate relay OUT1 common from ground...

Page 10: ...C 20VA transformer Optional if not used connect 10K resistor between terminals 9 and 10 IN4 StarLink BATTERY RED BLACK 8 9 10 N C COM N O J2 Note Battery leads are not power limited 10k 10k 10k TELCO...

Page 11: ...s 1 and 2 observing polarity 10k 12V or 24V AUX PWR 10k 10k Refer to section SUPPLYING POWER DO NOT USE EOLR EOLR J2 jumper off This connection only used with Power Supply SLE ULPS R These connections...

Page 12: ...ol Panel PC Board Refer to section SUPPLYING POWER Not required if JP2 shunt is removed and FACP monitors TELCO 2 Program only TELCO 1 supervision Note Connect IN2 to a panel output used for identifyi...

Page 13: ...telephone connections primary and secondary for supervision and central station reporting through the StarLink SLE LTEVI FIRE radio By removing the JP2 shunt and enabling the feature Tip Ring Wiring F...

Page 14: ...that opening the enclosure door will cause a tamper alarm Wiring a normally closed sensor loop for tamper supervision wire to a zone on the control panel GEM Tamperkit consists of Description QTY SC2...

Page 15: ...TRF12 T123 TRANSFORMER FOR CONNECTION TO SLE CHARGER BOARD UL LISTED SURFACE OR FLUSH MOUNT OUTLET BOX AND NON SWITCHED RECEPTACLE WALL TRANSFORMER SECONDARY WIRING CONDUIT LIMITED TO 20 FEET MAXIMUM...

Page 16: ...ay not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all c...

Reviews: