NAPCO GEMINI GEM-P1664 Programming Instructions Manual Download Page 43

L

 NAPCO Security Systems  

X

  GEM-P1664 Programming Instructions 

 

Page 43

 

WI1423A  1/06 

ZONE OPTIONS - ZONES 1 TO 16 (ADDRESS 0900-1016) 

Direct A

d

dress 

Program 

Mode 

 

ZONE OPTIONS 

ZONES 13-16    

LEFT DATA VALUES 

 

ADDRESS 

ZONES 9-12            

RIGHT DATA VALUES 

ZONES 5-8  

 LEFT DATA VALUES 

 

ADDRESS  

ZONES 1-4  

 RIGHT DATA VALUES 

 

 

ZN16  ZN15  ZN14  ZN13  L  ADDR  R  ZN12  ZN11  ZN10  ZN9  ZN8  ZN7  ZN6  ZN5 

L  ADDR  R  ZN4  ZN3  ZN2  ZN1 

 

50ms Loop Response 

(A) 

 

0964 

 

 

0900 

 

 

Priority 

 

0965 

 

 

0901 

 

 

Priority with Bypass 

 

0966 

 

 

0902 

 

 

Auto-Bypass 

 

0967 

 

 

0903 

 

 

Selective Bypass 

 

0968 

 

 

0904 

 

 

Keyswitch Arming 

 

0969 

 

 

0905 

 

 

Auto-Bypass Re-entry 

 

0970 

 

 

0906 

 

 

Pre-Alarm Warning 

 

0971 

 

 

0907 

 

 

Never Arm 

 

0972 

 

 

0908 

 

 

24-Hour Zone 

 

0973 

 

 

0909 

 

 

Alarm Output 

 

0974 

 

 

0910 

 

 

 

Pulsed Alarm Output 

 

0975 

 

 

0911 

 

 

PGM1 Output 

 

0976 

 

 

0912 

 

 

PGM2 Output 

 

0977 

 

 

0913 

 

 

 

Entry/Exit 1 

 

0978 

 

 

0914 

 

 

Entry/Exit 2 

 

0979 

 

 

0915 

 

 

 

Exit/Entry Follower 

 

0980 

 

 

0916 

 

 

Auto Reset 

 

0981 

 

 

0917 

 

 

Swinger Shutdown 

 

0982 

 

 

0918 

 

 

 

Chime 

 

0983 

 

 

0919 

 

 

Abort Delay 

 

0984 

 

 

0920 

 

 

Power-up Delay 

 

0985 

 

 

0921 

 

 

Day Zone Open 

 

0986 

 

 

0922 

 

 

Day Zone Short 

 

0987 

 

 

0923 

 

 

Alarm on Day Zone 

 

0988 

 

 

0924 

 

 

 

Alarm Telco 1 

 

0989 

 

 

0925 

 

 

Alarm Restore 1 

 

0990 

 

 

0926 

 

 

Trouble Telco 1 

 

0991 

 

 

0927 

 

 

Trouble Restore 1 

 

0992 

 

 

0928 

 

 

Alarm Telco 3 

 

0993 

 

 

0929 

 

 

Alarm Restore 3 

 

0994 

 

 

0930 

 

 

Trouble Telco 3 

 

0995 

 

 

0931 

 

 

Trouble Restore 3 

 

0996 

 

 

0932 

 

 

No EOL Resistor 

 

0997 

 

 

0933 

 

 

Trouble on Open 

 

0998 

 

 

0934 

 

 

Trouble on Short 

 

0999 

 

 

0935 

 

 

 

Zone Area 1 

 

1000 

 

 

0936 

 

 

Zone Area 2 

 

1001 

 

 

0937 

 

 

Interior (Stay) Bypass 

 

1004 

 

 

0940 

 

 

Keypad Sounder on Alarm 

 

1005 

 

 

0941 

 

 

 

2-Wire Smoke Detectors 

(B) 

(•)  1006  (•) 

8 4 

 

0942  (•) 

 

 

Fire (C) 

 

1007 

 

 

0943 

 

 

Fire Alarm Verification 

(C) 

 

1008 

 

 

0944 

 

 

RESERVED 

(•)  1009  (•) 

(•)  0945  (•) 

 

Zone ANDing Group 1 

 

1010 

 

 

0946 

 

 

Zone ANDing Group 2 

 

1011 

 

 

0947 

 

 

Zone ANDing Group 3 

 

1012 

 

 

0948 

 

 

Zone ANDing Group 4 

 

1013 

 

 

0949 

 

 

Sensor Watch 

 

1014 

 

 

0950 

 

 

RESERVED 

 

1015 

 

 

0951 

 

 

Chime 2 

 

1016 

 

 

0952 

 

 

 
 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 

 

 When the Easy Program Menu is used, these features are enabled by default. 

  

Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). 

  

Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).  Disable Auto-Reset on non-fire zones for SIA CP-01 installations. 

 

Zone Area 3 

 

1002 

 

 

0938 

 

 

Zone Area 4 

 

1003 

 

 

0939 

 

1. 

Select

 the desired zone option. 

ZONE OPTIONS 

50ms Loop Response 
Priority 
Priority with Bypass 
Auto-Bypass 
Selective Bypass 

3. 

Search table

 below for data entry. 

4. 

Enter data

 in address locations (left and right 

digits).  Press [Enter] or [ON/OFF] to save. 

ADDR 

blank (•)  0490 

ADDRESS LOCATION  

NOTE:

  Dark shaded boxes = option not available.   

See Direct Address Programming Example page 22. 

4

8

2 1

DIGIT VALUE DATA ENTRY

Blank (

.

)

4

8

2 1

1

4

8

2 1

2

8

1

2

4

3

4

8

2 1

4
5

4

8

2 1

4

8

2 1

6

4

8

2 1

7

4 2 1

DIGIT VALUE DATA ENTRY

8

4 2 1

9

4 2 1

0

1

2

4

B

4 2 1

C
D

4 2 1
4 2 1

E

4 2 1

F

8
8
8
8
8
8
8
8

Step 1 

Step 4  Step 4 

Step 4  Step 4 

Step 2 

Step 2 

Step 2 

Step 2 

See steps listed at 
bottom of page 

For notes (A), (B) and (C), see next page. 

2. 

Enable

 desired options for each zone 

by drawing a circle   around its 
corresponding binary data value.  

NOTE:

 

No circle = feature disabled. 

Summary of Contents for GEMINI GEM-P1664

Page 1: ...ck Start for GEM K3DGTL 1 Refer to the wiring diagram connect Siren Aux Power PGM Output Remote Bus Earth Ground Zone and Tele phone Wiring NOTE See Installation Instructions WI1424 2 Connect AC power...

Page 2: ...al are depicted using the K Se ries keypads the manual applies to both the classic and the K Series keypads Program Mode is the same for both keypads only the button names have changed as follows The...

Page 3: ...verview 20 Accessing Direct Address Program Mode 20 Keypad Address Program Mode Display 21 Direct Address Program Mode Keypad Commands 21 Direct Address Programming Example 22 Conventions Used in this...

Page 4: ...gram Mode Keypad Programming The Direct Address Program Mode is an extension of the Dealer Program Mode wherein data is entered at the keypad by specific location This mode is accessed from the Easy M...

Page 5: ...4 Hour Zones in Area 1 Chime Zones in Area 1 Chime 2 Zones in Area 1 Exit Entry2 Zones in Area 1 50mS Loop Response Zones Note 750mS is required for Loop Response time in UL installations Aux Output A...

Page 6: ...ire Zones in Area 1 Appears for New Panel Only Enter the zone number of any zones which are to be used as Fire Zones both 2 wire 4 wire or wireless Valid entries are from 01 to 64 Directly enter each...

Page 7: ...ct pulsating tone when zone is faulted Exit Entry2 Zones in Area 1 New Program Only Enter the zone numbers of zones to be used as Exit Entry 2 zones Valid entries are from 01 to 64 Directly enter each...

Page 8: ...s the NEXT YES button to enable Press the PRIOR NO button to continue The SIA CP 01 Features are designed to reduce the incidence of false alarms See WI1424 Installer Pro gramming Quick Reference Char...

Page 9: ...User Codes with Area 1 4 Options Press R once to set the cursor to the User Code Use the number buttons 1 through 9 to enter a code from 3 to 6 digits Enter up to 6 digits 4 digits is recommended in t...

Page 10: ...s is normally used to activate a door strike while an area is disarmed Also program Access Control on PGM2 Output Address 0719 and PGM2 Output Access Control Timeout Address 0711 Ambush There are two...

Page 11: ...tons on a system each reporting to a Central Station or a pager and or annunciating on a keypad the key fob zone number with description location To assign a key fob to a zone program the keyfob as yo...

Page 12: ...ess the U button Data entry is not allowed NOTE Enter Easy Menu Driven Program Mode to program system again Cold Start Erases Entire Program This erases the entire program including Dealer Program by...

Page 13: ...structions Fire Zones Appears for New Panel Only Enter the zone number of any Fire Zones both 2 wire 4 wire or wireless Valid entries are from 01 to 64 Directly enter each zone number including leadin...

Page 14: ...the zone numbers of zones to be used as Exit Entry zones Valid entries are from 01 to 64 Directly enter each zone number including leading zeros Press U to save and repeat for any additional zone s pr...

Page 15: ...NEXT YES button to program all zones except 24 Hr fire zones for No End Of Line Resistor Press the PRIOR NO button to continue NOTE Do not program this feature for UL Installations Enable Telco Line F...

Page 16: ...Options for each code Refer to the tables below for available data entries for User Options Press R once to set cursor to the User Number and enter the desired User Number Press R once again to set th...

Page 17: ...s and U save Notes 1 For User Code press G 0 for Blank Space 2 For User Options press 0 for Blank Space 28 INTERIOR BYPASS FIRE TBL SYS TBL CHIME INTERIOR BYPASS FIRE TBL SYS TBL CHIME Quick Enroll Me...

Page 18: ...nes can be assigned providing multiple wireless panic buttons on a system each reporting to the Central Station or a pager and or annunciating on a keypad the key fob zone number with description loca...

Page 19: ...s C to silence the keypad Direct Entry 33 INTERIOR BYPASS FIRE TBL SYS TBL CHIME INTERIOR BYPASS FIRE TBL SYS TBL CHIME rE ZONE DESCRIPTIONS GEM K3DGTL cannot be used to enter Zone Descriptions To ent...

Page 20: ...to change all the options It consists of multiple address locations with two data entry locations each left and right as shown in the adjacent diagram ACCESSING DIRECT ADDRESS PROGRAM MODE LEFT DIGIT...

Page 21: ...GTL GEM K3DGTL Keypads To access press C in Dealer Program Mode 1 Toggle Cursor to 4 digit ad dress field using the R button 2 Enter address Number directly using number buttons 0 9 3 Enter Data direc...

Page 22: ...ith your program ENTRY TOTAL PRESS N KEYPAD DISPLAYS 8 4 2 1 blank 0 8 4 2 1 1 1 8 4 1 2 2 2 8 4 3 3 3 8 2 1 4 4 4 8 2 5 5 5 8 1 6 6 6 8 7 7 7 4 2 1 8 8 8 4 2 9 9 9 4 1 10 G 0 0 4 11 G 1 B 2 1 12 G 2...

Page 23: ...h address CONVENTIONS USED IN THIS MANUAL The Keypad Programming Worksheets in the back are provided as an address programming reference to help the installer modify his custom default program or to m...

Page 24: ...he programming option data entry from the tables shown 3 Enter the selected data entry in the boxes shown 4 For more information on a programming option refer to the Glossary at the end of this manual...

Page 25: ...gnore location 4 Press U or D to save PAGER FORMAT OPTIONS ADDRESS 0546 0547 LEADING DIGITS FOR PAGER FORMAT In Pager Format reporting the message typically begins with 00 However for some pager servi...

Page 26: ...4 2 1 PGM2 Output 8 4 2 1 0839 8 4 2 1 Report Event Telco 1 8 4 2 1 0840 8 4 2 1 Report Restore Telco 1 8 4 2 1 0841 8 4 2 1 Report Event Telco 3 8 4 2 1 0842 8 4 2 1 Report Restore Telco 3 8 4 2 1 0...

Page 27: ...AMBUSH Pulsed Alarm Output 8 4 2 1 0872 8 4 2 1 Alarm Output 8 4 2 1 0873 8 4 2 1 PGM1 Output 8 4 2 1 0874 8 4 2 1 PGM2 Output 8 4 2 1 0876 8 4 2 1 Report Event Telco 1 8 4 2 1 0877 8 4 2 1 Report Ev...

Page 28: ...S 1 Enable Zone Doubling Zones 9 16 2 Wireless Trouble Activates Telco 1 4 Wireless Trouble Activates Telco 3 8 Enable Alarm Output on Telco Fail only when Armed RIGHT DATA VALUES CIRCLE SYSTEM OPTION...

Page 29: ...r Recent Close 8 Enable CP 01 Limits 1 Select the desired option by circling the data values for each digit left and right 2 Add the data values ex F 15 1 2 4 8 from the selected options See page 23 3...

Page 30: ...er depends on Easy Menu Question CENTRAL PHONE Default blank across digits 1 20 for CS Receiver Telephone Numbers 2 and 3 CS Receiver 1 LEFT RIGHT Format blank ADDRESS 0460 CS Receiver 2 LEFT RIGHT Fo...

Page 31: ...HT DIGITS 1 4 0664 0665 0666 0667 CS Telco 1 Sub scriber Opening Closing ID Number Area 4 ADDRESS 0572 0575 RIGHT DIGITS 1 4 0572 0573 0574 0575 CS Telco 1 Sub scriber Opening Closing ID Number Area 3...

Page 32: ...Fail to Close 0704 Keyfob Low Battery 0705 CS SYSTEM REPORTING OPTIONS ADDRESS 0670 0705 CS AREA SYSTEM REPORTING OPTIONS ADDRESS 0785 0786 0788 Default blank blank LEFT DIGIT SUM RIGHT DIGIT SUM ADD...

Page 33: ...55 1468 to enable EZM Group Options PULSE EVENT CODE will be the first digit of the 2 digit reporting code The second digit will be the second digit of the reporting zone For example for zone 9 addres...

Page 34: ...28 User 27 User 26 User 25 8 4 2 1 8 4 2 1 RIGHT DATA VALUES LEFT DATA VALUES ADDRESS 0804 User Opening Telco 1 User 40 User 39 User 38 User 37 LEFT RIGHT User 36 User 35 User 34 User 33 8 4 2 1 8 4 2...

Page 35: ...28 User 27 User 26 User 25 8 4 2 1 8 4 2 1 RIGHT DATA VALUES LEFT DATA VALUES ADDRESS 0822 User Opening Telco 3 User 40 User 39 User 38 User 37 LEFT RIGHT User 36 User 35 User 34 User 33 8 4 2 1 8 4 2...

Page 36: ...UP OPTIONS Up to 14 Groups of 4 Zones each may be pro grammed depending on the number of Zones used and which EZM mod ules are connected Each Group represents 4 Zones 1 Select EZM type from the table...

Page 37: ...VALUES CIRCLE RESERVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 Burglary Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1475 RIGHT DA...

Page 38: ...UES CIRCLE RESERVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 Pulsed Burg Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1479 RIGHT DA...

Page 39: ...VALUES CIRCLE RESERVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 PGM1 Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1483 RIGHT DATA...

Page 40: ...VALUES CIRCLE RESERVED 1 RESERVED 2 RESERVED 4 RESERVED 8 Default blank one 1 PGM2 Output Turns Off upon Disarm LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES 1 ADDRESS 1487 RIGHT DATA...

Page 41: ...ess locations above 3 Press U or D to save KEYPAD OPTIONS ADDRESS 1425 1431 1440 1446 RIGHT OPTION blank Disabled 1 Active Keypad KEYPAD ASSIGNMENT KEYPAD NO KEYPAD OPTIONS LEFT DATA VALUES CIRCLE ADD...

Page 42: ...depressed and held down for 2 seconds the date will display for 5 seconds In addition three addresses must be enabled either via Quickloader or via direct address programming in order for the Tempera...

Page 43: ...31 8 4 2 1 Trouble Restore 3 8 4 2 1 0996 8 4 2 1 8 4 2 1 0932 8 4 2 1 No EOL Resistor 8 4 2 1 0997 8 4 2 1 8 4 2 1 0933 8 4 2 1 Trouble on Open 8 4 2 1 0998 8 4 2 1 8 4 2 1 0934 8 4 2 1 Trouble on Sh...

Page 44: ...8 4 2 1 Entry Exit 1 8 4 2 1 1106 8 4 2 1 8 4 2 1 1042 8 4 2 1 Entry Exit 2 8 4 2 1 1107 8 4 2 1 8 4 2 1 1043 8 4 2 1 Exit Entry Follower 8 4 2 1 1108 8 4 2 1 8 4 2 1 1044 8 4 2 1 Auto Reset 8 4 2 1...

Page 45: ...1 8 4 2 1 1185 8 4 2 1 Alarm Restore 3 8 4 2 1 1250 8 4 2 1 8 4 2 1 1186 8 4 2 1 Trouble Telco 3 8 4 2 1 1251 8 4 2 1 8 4 2 1 1187 8 4 2 1 Trouble Restore 3 8 4 2 1 1252 8 4 2 1 8 4 2 1 1188 8 4 2 1...

Page 46: ...8 4 2 1 Entry Exit 1 8 4 2 1 1362 8 4 2 1 8 4 2 1 1298 8 4 2 1 Entry Exit 2 8 4 2 1 1363 8 4 2 1 8 4 2 1 1299 8 4 2 1 Exit Entry Follower 8 4 2 1 1364 8 4 2 1 8 4 2 1 1300 8 4 2 1 Auto Reset 8 4 2 1...

Page 47: ...ADDRESS 1544 1548 RELAY EVENT 12 1544 1545 1546 1547 L R L R L R L R L R 1548 RELAY AREA Timeout Event ID COND ADDRESS 1549 1553 RELAY EVENT 13 1549 1550 1551 1552 L R L R L R L R L R 1553 RELAY AREA...

Page 48: ...tions left and right digit STEP 5 RELAY EVENT CONDITION OPTIONS Each relay event can be assigned an alarm type and an activation condition also select a timeout type for each 5A Select Alarm Type and...

Page 49: ...Fail D 1 EZM Fail D 2 Quickloader Device Control D 5 General System Alarm D 8 Area 1 General System Alarm D 9 Area 2 General System Alarm D 0 Area 3 General System Alarm D B Area 4 General System Alar...

Page 50: ...D to save NOTE These timers apply only to Supervised RF Transmitters see RF Transmitters in Easy Menu Driven Mode Programming Default blank blank from address 2029 2044 RF SUPERVISORY TIMER RF TRANSMI...

Page 51: ...wer fails time and date restarts at 00 00 00 and a date of 01 01 04 January 1 2004 GEM RP1CAe2 Keypad 2286 XX GEM RP2ASe2 Keypad 2286 XX USER PROGRAM MODE PRELIMINARY INFORMATION The User Program Mode...

Page 52: ...6 digits directly using number buttons 0 9 4 Press the U button to save each code NOTE Press G 0 button to clear character at cursor To continue press P or Q button G E M I N I ARMED COMPUTERIZED SECU...

Page 53: ...7 GEM RP2ASe2 GEM K2AS GEM RP3DGTL GEM K3DGTL and or GEM RP4RFC GEM K4RF keypads may be connected to the panel Keypads 1 7 Each must be configured for a keypad address In addition the keypad may be c...

Page 54: ...TELCO 1 ZONE OPTION 43 44 45 46 ALARM TELCO 3 ZONE OPTION 43 44 45 46 AREA 1 SYSTEM EVENT TROUBLE 26 AREA 2 SYSTEM EVENT TROUBLE 26 AREA 3 SYSTEM EVENT TROUBLE 27 AREA 4 SYSTEM EVENT TROUBLE 27 AREA...

Page 55: ...RAM MODE KEYPAD COMMANDS 21 DISABLE ON OFF AS EASY EXIT ADDRESS 2051 29 DISABLE 2ND CALL ANS MACHINE OVERRIDE ADDRESS 142428 DISABLE AUTO DIAL TONE DETECT ADDRESS 0788 32 DISABLE CALL WAITING ON 1ST A...

Page 56: ...FIRE ALARM VERIFICATION ZONE OPTION 43 FIRE ALARM VERIFICATION ZONE OPTION 44 45 46 FIRE ZONES 13 FIRE ZONES IN AREA 1 6 FUNCTION MODE 4 GAS ALARM MODEM CODE 33 GEM P1664 WIRING DIAGRAM 64 GEM RP2ASE2...

Page 57: ...PTION 43 44 45 46 PRIORITY AREA ARMING 36 PRIORITY WITH BYPASS ZONE OPTION 43 44 45 46 PROGRAMMING STEPS 23 PROGRAMMING TIMEOUTS 24 PROGRAMMING USER CODES 52 PULSE ALARM OUTPUT TIMEOUT ADDRESS 1415 25...

Page 58: ...UBLE ON SHORT ZONE OPTION 43 44 45 46 TROUBLE RESTORE 1 ZONE OPTION 43 44 45 46 TROUBLE RESTORE 3 ZONE OPTION 43 44 45 46 TROUBLE TELCO 1 ZONE OPTION 43 44 45 46 TROUBLE TELCO 3 ZONE OPTION 43 44 45 4...

Page 59: ...le Zone Number on Pulse Alarm 30 ADDRESS 0505 Single Digit Only 30 ADDRESS 0505 Sum Check 30 ADDRESS 0526 0545 Callback Telephone Number 25 ADDRESS 0526 0545 DOWNLOAD CALLBACK OPTIONS 25 ADDRESS 0546...

Page 60: ...M OPTIONS 28 ADDRESS 1421 Access Control on PGM2 Output 28 ADDRESS 1421 Auto Bell Test on Arming 28 ADDRESS 1421 Auto Reset after Burglary Output Timeout 28 ADDRESS 1421 Disable Keypad Instant Mode 28...

Page 61: ...24 ADDRESS 2051 Disable ON OFF as Easy Exit 29 ADDRESS 2051 Disable System Trouble Audible Timeout 29 ADDRESS 2051 Enable K Series Style Keypads 29 ADDRESS 2051 Enable Cancel Report to Telco 3 29 ADD...

Page 62: ...X GEM P1664 Programming Instructions L NAPCO Security Systems Page 62 WI1423A 1 06 NOTES...

Page 63: ...L NAPCO Security Systems X GEM P1664 Programming Instructions Page 63 WI1423A 1 06 NOTES...

Page 64: ...X GEM P1664 Programming Instructions L NAPCO Security Systems Page 64 WI1423A 1 06 GEM P1664 WIRING DIAGRAM 550mA 550mA 1 12 MODEL DELAY SEC...

Reviews: