NAPCO GEM-SMK-CO-E Installation Instructions Manual Download Page 1

GEM

-

SMK

-

CO

-

E Smoke / Carbon Monoxide Detector Installation Instructions

 

1

 

 

and/or CO is detected, the unit sounds a local alarm, and the 

transmitter sends an alarm signal to the supervised receiver.  

The  alarm  signal  is  repeated  every 

10 

seconds  thereafter  if 

smoke or CO is still present.  A restore report is sent when the 

smoke/CO detection chamber clears.  Smoke and CO super-

visory status reports are sent from the unit every hour.  Each 

GEM

-

SMK

-

CO

-

detector  is  assigned  two  RF  IDs  for  each 

function 

--

  an  ID  for  smoke  and  another  ID  for  CO.    Coding 

switches are not required.  

Note: 

 The 

GEM

-

SMK

-

CO

-

E

 must 

be  installed  in  accordance  with  the  National  Fire  Protection 

Association NFPA 720.  

 

 

 

The 

GEM

-

SMK

-

CO

-

E

 includes the following features: 

 

• 

Easy to install

 

• 

Continuous monitoring for carbon monoxide and smoke

 

• 

Loud 85dB alarm sounder

 

• 

Test/Silence

 button 

 

• 

Continuous self

-

diagnostic testing

 

• 

10 year detector life.  Approximately 3 year battery life un-

der normal operating conditions (reports low battery condi-

tion to assist with maintenance)

 

 

 

SPECIFICATIONS

 

 

ETL  Certified,  conforms  to  UL  2075  that  has  already  estab-

lished the carbon monoxide concentrations and exposure time 

standards  for  this  detector:    At  70ppm,  the  detector  must 

alarm  within 60

-

240 minutes.   At 150ppm, the detector must 

alarm  within  10

-

50  minutes.    At  400ppm,  the  detector  must 

alarm within 4

-

15 minutes.  

 

 

Electrical Ratings

 

Input Power:  

Powered by a replaceable 3

-

volt lithium bat-

tery.    Use  one  3

-

volt  lithium Duracell  DL123A  or  Pana-

sonic CR123A.  

 

 

Dimensions (W×L×D):  

5

-

3/8 x 5

-

3/8 x 2

-

1/8" (13.7 x 13.7 

x 5.4cm)

 

 

Operating Environment

 

Temperature:  

40°F to 100°F (4.4°C to 37.8°C)

 

 

Regulatory Information

 

Rating:

    This  detector  has  been  evaluated  by  ETL  and 

conforms to the CO detector sensitivity limits of UL 2075 

and also conforms to Smoke Detectors UL 268, as indi-

cated  in  the 

SPECIFICATIONS 

section  above.   

Note: 

 

When  used  as  a  Smoke

-

CO  detector  the  unit  must  be 

installed in accordance with NFPA 720.  When used as a 

smoke detector, install in accordance with NFPA 72.

 

 

Environmental  Class:   

Indoor,  in  accordance  with  the 

Operating Environment specifications.

 

 

 

INFORMATION ABOUT CARBON MONOXIDE

 

 

Carbon monoxide, also known as "CO", is a highly dangerous 

poisonous gas because it is colorless, odorless, tasteless, and 

very toxic.  The presence of CO gas inhibits the blood's ability 

to transport oxygen throughout the body, eventually leading to 

brain damage.  In any enclosed space (home, office, recrea-

tional vehicle or boat) even a small accumulation of CO gas 

can  be  dangerous.    Although  many  products  of  combustion 

WI2546.aLF  12/23

 

GEM

-

SMK

-

CO

-

E  SUPERVISED DIGITAL WIRELESS 

 

SMOKE / CARBON MONOXIDE DETECTOR

 

INSTALLATION INSTRUCTIONS

 

333 Bayview Avenue, Amityville, New York 11701

 

For Sales and Repairs, (800) 645

-

9445

 

For Technical Service, (800) 645

-

9440 or visit us at

 

Tech.NapcoSecurity.com

 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC

 

© NAPCO 2023

 

TABLE OF CONTENTS

 

Introduction ................................................................................................. 1 

Specifications .............................................................................................. 1 

Product View ............................................................................................... 1 

Information About Carbon Monoxide......................................................... 1 

Possible Symptoms of Carbon Monoxide Poisoning ............................... 2 

Situations Where Detector is Ineffective ................................................... 2 

Locations to Install Your Detector ............................................................. 2 

Locations Not to Install Your Detector....................................................... 4 

Installing Your Detector .............................................................................. 4 

Warning Signals (Details) ........................................................................... 5 

Summary of Warning Signals ..................................................................... 6 

General Maintenance .................................................................................. 6 

If CO Alarm Activates.................................................................................. 7 

Actions to Take After the Problem is Corrected ........................................ 7 

If Smoke Alarm Activates ........................................................................... 7 

Limitations of Wireless Devices ................................................................. 7 

Limited Warranty ......................................................................................... 8 

(Front View)

 

(Rear View)

 

(Mounting Bracket)

 

INTRODUCTION

 

 

The 

GEM

-

SMK

-

CO

-

is  a  high

-

quality  combination  photoe-

lectric smoke detector (conforms to UL 268) and carbon mon-

oxide detector (conforms to UL 2075) and is equipped with a 

supervised  digitally  coded  radio  transmitter.    It  is  compatible 

with  NAPCO's  GEM

-

RECV  and  GEMC

-

RECV  series  super-

vised receivers that monitor alarms, restores, low battery, tam-

per, and status; for use with NAPCO's GEM and GEMC se-

ries Control Units.  

Note: 

 See Control Unit installation instruc-

tions for compatibility.  

 

 

During  normal  operation,  the  green  LED  on  the 

GEM

-

SMK

-

CO

-

E

  flashes  once  every  50  seconds.   

As  soon  as  smoke 

Summary of Contents for GEM-SMK-CO-E

Page 1: ...used as a smoke detector install in accordance with NFPA 72 Environmental Class Indoor in accordance with the Operating Environment specifications INFORMATION ABOUT CARBON MONOXIDE Carbon monoxide al...

Page 2: ...heating oil kerosene coal charcoal gasoline and wood This incomplete combus tion of fuel can occur in any device which depends on burning for energy or heat such as furnaces boilers room heaters hot...

Page 3: ...egistered trademarks of the National Fire Protection Associa tion Inc Quincy MA 02269 units smoke detectors should be installed in all rooms halls storage areas basements and attics in each family liv...

Page 4: ...places where combustion particles are normally pre sent If a 20 foot distance is not possible e g in a mobile home install detector as far away from the combustion particles as possible preferably on...

Page 5: ...ound until the arm disarm code is entered at the control panel keypad TEST FEATURE After installation verify operation of the de tector siren LEDs and battery by a push release of the Test Silence but...

Page 6: ...he following Staining or stripping wood painting wall papering or using adhesives Store the detector in a plastic bag during any of these activities to help protect the sensor from damage Be sure to r...

Page 7: ...ng properly again IF SMOKE ALARM ACTIVATES Never ignore the sound of the alarm Check for signs of fire or smoke throughout the premises If smoke is discovered follow the steps list below Thoroughly fa...