NAPCO Security Systems
LIBRA LIB-P432EX Series Programming Instructions
Page 7
Interior (Stay) Bypass Zones in Area 1
(Appears for New Panel Only)
Directly enter the zone number of any zones which are to be used as Interior Follower Zones. Valid entries are
from 01 to 32. Directly enter each zone number, including leading zeros. Use number buttons
1
through
9
.
NOTE:
Press
0
for a zero. Press
u
to save and then repeat for any additional zone(s). Press
NEXT ("
r
" or
p
) to proceed.
NOTE:
All Interior Follower zones will also be automatically programmed as
“Exit/Entry Follower” and "Power Up Delay" zones. If you are programming a multiple Area system, enter the total
number of zones required for Areas 1-4. The Direct Address Program Mode can then be used to remove zones
from Area 1 and place them in Areas 2, 3 or 4. See Zone Options.
24 Hour Zones in Area 1
(New Program Only)
•
Enter the zone numbers of zones to be used as 24 Hour zones.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
u
to save and repeat for any additional zone(s); press NEXT ("
r
" or
p
) to proceed.
Chime Zones in Area 1
(New Program Only)
•
Enter the zone numbers which are to be used as Chime Zones.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
u
to save and then repeat for any additional zone(s), press NEXT ("
r
" or
p
) to proceed.
NOTE:
A chime time of 2 seconds will be automatically programmed.
Chime 2 Zones in Area 1
(New Program Only)
•
Enter the zone numbers which are to be used as Chime 2 Zones.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
u
to save and then repeat for any additional zone(s), Press NEXT ("
r
" or
p
) to proceed.
NOTE:
A chime time of 2 seconds will be automatically programmed.
Chime 2 zones give a distinct pulsating tone when zone is faulted.
Exit/Entry2 Zones in Area 1
(New Program Only)
•
Enter the zone numbers of zones to be used as Exit/Entry 2 zones.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
u
to save and repeat for any additional zone(s); press NEXT ("
r
" or
p
) to proceed.
NOTE:
An Exit/Entry 2 Entry Time of 30 sec. will automatically be programmed.
50 mS Loop Response Zones
(New Program Only)
•
Enter the zone numbers of zones to be have a 50mS loop response.
Note:
Time can also be adjusted
via address 2280.
•
Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros.
•
Press
u
to save and then repeat for any additional zone(s), Press NEXT ("
r
" or
p
) to proceed.
AUX Output Activated on Alarm Zones
(New Program Only)
•
Enter the zone numbers of zones to activate the PGM2 output upon alarm.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
u
to save and then repeat for any additional zone(s), Press NEXT ("
r
" or
p
) to proceed.
NOTE:
An Aux Output Timeout of 15 Minutes will automatically be programmed.
Sensor Watch Zones
(New Program Only)
•
Enter the zone numbers of zones to be Sensor Watch zones.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
u
to save and then repeat for any additional zone(s), Press NEXT ("
r
" or
p
) to proceed.
NOTE:
A Sensor Watch Time of 24 hours will automatically be programmed.
Keypad Sounder On Alarm Zones
(New Program Only)
•
Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.
•
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
•
Press
u
to save and then repeat for any additional zone(s), press NEXT ("
r
" or
p
) to proceed.
(Direct Entry)
E n t F o l
Z n # X X
(Direct Entry)
E n t 2 4 H
Z n # X X
(Direct Entry)
E n t C Z 1
Z n # X X
(Direct Entry)
E n t K P S
Z n # X X
(Direct Entry)
E n t S W
Z n # X X
(Direct Entry)
E n t A u x
Z n # X X
(Direct Entry)
E n t 5 0 m
Z n # X X
(Direct Entry)
E n t E E 2
Z n # X X
(Direct Entry)
E n t C Z 2
Z n # X X