LIBRA LIB-P432EX Series Programming Instructions
NAPCO Security Systems
Page 28
SYSTEM OPTIONS (ADDRESS 1420-1424)
1. Select the desired option by circling
the data values for
each digit (left and right).
2. Add the data values (ex: F=15=(1+2+4+8) from the selected
options. See page 23).
3. Enter in address location (left and right digits).
NOTE:
Dark
shaded data value box shows option not available.
4. Press
u
to save.
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 1420
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 1421
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 1422
[Default = (4) blank (•)]
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 1424
[Default = blank (•) blank (•)]
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 1423
RIGHT DATA
VALUES
(CIRCLE
)
SYSTEM OPTIONS
1
Interior Normally By-
passed
2
Enable Global Ambush
Code ***
4
Reset Day Zone with Arm/
Disarm Only
8
Enable Residential Fire
RIGHT DATA
VALUES
(CIRCLE
)
SYSTEM OPTIONS
1
Auto Bell Test
on Arming
2
Auto Reset after Burglary
Output Timeout
4
Suppress Bypass
Reminder when Armed
8
Enable Local Alarm on
First Zone AND Trip
RIGHT DATA
VALUES
(CIRCLE
)
SYSTEM OPTIONS
1
Opening Report Only after
Alarm Report
2
Closing Report Only on
Conditional Close
4
Incl. Sel./Grp. Bypass in
Cond. Close /Status
8
Status Report
RIGHT DATA
VALUES
(CIRCLE
)
SYSTEM OPTIONS
1
Enable Zone Doubling
(Zones 9-12)
2
Wireless Trouble
Activates Telco 1
4
Wireless Trouble
Activates Telco 3
8
Enable Alarm Output on Telco
Fail only when Armed
RIGHT DATA
VALUES
(CIRCLE
)
SYSTEM OPTIONS
1
Automatic Interior Bypass/
Easy Exit
RESERVED
RESERVED
8
Resound on Wireless
Smoke Low Battery
SYSTEM OPTIONS
LEFT DATA
VALUES
(CIRCLE
)
Disable Keypad Function
Mode Download
1
Disable Callback
Download
2
Chirp Output on Keyfob
Arm/Disarm
4
Change Pulse Output to
Temporal Output
§
8
SYSTEM OPTIONS
LEFT DATA
VALUES
(CIRCLE
)
Access Control on
PGM2 Output
1
Maintained Keyswitch
Arming
2
Enable Manager's Mode
4
Disable Keypad Instant
Mode
8
SYSTEM OPTIONS
LEFT DATA
VALUES
(CIRCLE
)
RESERVED
Enable AutoArm if not
closed at end of Window
2
Enable Keypad Time/
Date Display
4
Disable Zone Fault
Scrolling
8
SYSTEM OPTIONS
LEFT DATA
VALUES
(CIRCLE
)
Don't Clear PGM2 Output
with Disarm
1
Disable 2nd Call Ans.
Machine Override
2
Enable Loop Supervision
4
Disable Code Required
for Bypass (Enable EZ Bypass)
8
SYSTEM OPTIONS
LEFT DATA
VALUES
(CIRCLE
)
Line-Fault Test only
when Armed**
1
Enable Line-Fault Test**
2
Inhibit System Trouble
Audible at Keypad
4
Select Alarm Output for
Keyfob Chirp
8
For Address 1423
: Default depends on Easy
Menu Question “
EZ ZONE DOUBLING? Y/N
”.
If yes, then [Default = •(blank) 1].
If no, then [Default = •(blank) •(blank)].
*NOTE: Address 1423:
Default depends on Easy Menu Question :"
EZ
ZONE DOUBLING? Y/N
". If yes, then [Default = 1]. If no, then [Default =
blank (•)].
**NOTE:
To select "Line-Fault Test only when Armed", you must also
select "Enable Line-Fault Test" at address 1423.
***NOTE:
If "Enable Global Ambush Code" in Address 1422 is selected, then
program the 2-digit "Global Ambush Code" in Address 2045. If Address
2045 is left blank (•), then, the 2-digit "Global Ambush Code" will be "99".
§This feature must be programmed in Fire Alarm applications.