Napa Carlyle DTW12 User Manual Download Page 1

DTW38 and DTW12 

Rev. 02/27/15

DTW38, DTW12

3/8" Torque Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-100 ft.-lbs.
1/2" Torque Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-250 ft.-lbs.
 

CW +/-2% CCW +/-2% of reading,

Torque Accuracy (*1)  . . . . . . . . . . . . . . . . . . . . . . . . . .10% to 100% of full scale
Angle Accuracy  . . . +/- 1% of r/- 1°, Angle Velocity 10°/sec ~180°/sec
Data Memory Values  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Peak Hold/Track
Unit Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ft-lb, in-lb, N-m, & kg-cm
Head Type  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed
Gear teeth  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Audible Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes
Buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
LED Indicator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 LED's
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 AA
Battery Life-Continuous Operation (*2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hrs
Battery Life-Standby (*2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Year
Operating Temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41ºF ~ 108ºF
Storage Temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -4ºF ~ 122ºF
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Up to 90% non-condensing

SPECIFICATIONS

AlwAys reAd  
instructions 
before using 
tools 

AlwAys weAr  
sAfety 
goggles

not 
wAterproof

DTW38, DTW12

3/8", 1/2" Dr. Digital Torque Wrenches

WARNING

Summary of Contents for Carlyle DTW12

Page 1: ...k Hold Track Unit Selection ft lb in lb N m kg cm Head Type Fixed Gear teeth 32 Audible Alarm Yes Buttons 6 LED Indicator 3 LED s Batteries 2 AA Battery Life Continuous Operation 2 60 Hrs Battery Life...

Page 2: ...curely so that it is resistant to impact shock while in transit Notes from Page 1 1 The accuracy of the readout is guaranteed from 10 to 100 of maximum range 2 To maintain the accuracy of the torque w...

Page 3: ...r Kit for DTW38 RSDTW12HRP Head Repair Kit for DTW12 No other internal parts are available due to the sensitivity of this professional model Please utilize the repair facility listed under the warrant...

Page 4: ...cont Step 2 Insert the pawl spring into the handle spring hole See Fig 2 Step 3 Place the steel ball on top of the pawl spring See Fig 3 Step 4 Insert the pawl with the square hole facing inward and t...

Page 5: ...the switch and the bottom of the pawl See Fig 5 are both pointing in the same direction Then fasten with the switch screw Step 6 Insert the driver into the ratchet head aligning the teeth on the drive...

Page 6: ...Unit of Measure Setting 2 Increase measurement UP 3 Decrease measurement Down 4 M Memory Mode 5 C Clear Value Return 6 On Off Hold for 3 seconds to power off Hold for 1 second to power on 4 5 3 2 1 6...

Page 7: ...on the face when a measurement is taken in the CCW rotation The arrow will also be present if the memory is accessed for a previous measurement taken in the CCW rotation M Indicates MEMORY There are 9...

Page 8: ...90 is indicated by a yellow LED 100 is indicated by a green LED and 110 is indicated by a red LED If a slight amount of force is applied during the 5 flash cycle the peak measurement will be shown fo...

Page 9: ...tes without use 2 Auto Shut Off Press ON OFF button for 3 seconds to Power off Set full scale of torque Press ON OFF button to set full scale of torque value Showing Torque Value After Power on you ar...

Page 10: ...5 of full scale torque value is applied Rotation is accumulated in angular degrees When the applied torque is released the accumulated angle value will flash and the buzzer will sound 2 Angle Setting...

Page 11: ...unidad libras pie pulg pie N m kg cm Tipo de Cabeza Fija Dientes de Engranaje 32 Alarma audible S Botones 6 Indicador DEL 3 l mparas DEL Bater as 2 AA Operaci n de vida continua de la bater a 2 60 hor...

Page 12: ...el transporte Notas de la p gina 1 1 La precisi n de la lectura est garantizada desde un 10 al 100 del rango m ximo 2 Para mantener la precisi n del torqu metro el calibrado debe realizarse una vez a...

Page 13: ...n de cabeza para DTW12 Ninguna otra parte est disponible debido a la sensibilidad de este modelo profesional Utilice por favor el centro de reparaci n alistado bajo la declaraci n de garant a para tod...

Page 14: ...quete en el agujero del resorte del mango Ver la fig 2 Paso 3 Coloque la bola de acero en la parte superior del resorte del trinquete Ver la fig 3 Paso 4 Inserte el trinquete con el agujero cuadrado o...

Page 15: ...ior del trinquete ver la fig 5 los dos est n apunt ndose en la misma direcci n Luego sujete con el tornillo del interruptor Paso 6 Inserte el conductor en la cabeza del trinquete alineando los dientes...

Page 16: ...e 2 Aumentar la medida ARRIBA 3 Disminuir la medida ABAJO 4 M Modo de memoria 5 C Borrar valor Volver 6 3 Encendido Apagado Sostenga por 3 segundos para apagarlo Sostenga por un segundo para encenderl...

Page 17: ...toma una medida en la rotaci n de CCW La flecha tambi n estar presente si se acceda la memoria por una medida previa tomada en la rotaci n de CCW M Indica MEMORIA Hay 99 ubicaciones de almacenamiento...

Page 18: ...el 90 por ciento con una luz amarilla DEL el 100 se indica por una luz DEL verde y el 110 ser indicado por una luz DEL roja Si se aplica una ligera fuerza durante el ciclo de 5 parpadeos la medida pi...

Page 19: ...completa de torsi n Presione el bot n ON OFF para ajustar la escala completa de valores de torsi n Mostrando los valores de torsi n Despu s del encendido usted est en el modo de mostrando valores de...

Page 20: ...alor de torsi n La rotaci n se acumula en grados angulares Cuando la torsi n aplicada se libera el valor del ngulo acumulado parpadear y el timbre sonar 2 Modo de ajuste de ngulo Paso 1 Presione el bo...

Reviews: