3.2 Power supply (Phoenix connector)
Permissible operating voltage
The permissible operating voltage of the Plug & Drive motor PD4-N lies within the
range +12 to +48 V DC and must not exceed 50 V or undershoot 11 V.
A charging condenser with minimum 4700 µF (10000 µF) must be provided for the
operating voltage to prevent exceeding the permissible operating voltage (e.g. during
braking).
Danger of electrical surges
Connect charging condensor with minimum 4700 µF!
An operating voltage > 50 V will destroy the output stage!
Mixing up the connections can destroy the output stage!
Never disconnect the motor when operating voltage is applied!
Never
disconnect lines when live!
Voltage supply connection diagram
Note:
Complete connection diagram, see Section 2.2.
Pin assignment
Pin no. Name
Wire no. ZK-PD4N
1 GND
1
2 Vcc
2
Accessories for voltage supply
Appropriate power packs and charging condensers are available as accessories:
Name Order
identifier
Power pack
NTS-xxV-yA
(xx=voltage: 12, 24 or 48 V, y=current: 2.5, 5 or 10 A)
Information on the selection of the required power supply unit
can be found in our FAQ on www.nanotec.com.
Charging
condenser
Z-K4700 or Z-K10000