Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Change history
Firmware version FIR-v1626: "Savable" entry changed from "no" to
"yes, category: application".
Description
This object is calculated as thousandths of the torque, e.g., the value "500" means "50%" of the rated
torque; "1100" is equivalent to 110%. The rated torque corresponds to the rated current in object
203B
h
:01.
The target torque may not exceed the peak torque (proportional to the peak current in 2031
h
).
6072h Max Torque
Function
The object describes the maximum torque for the Profile Torque and Cyclic Synchronous Torque
modes in tenths of a percent of the rated torque.
Object description
Index
6072
h
Object name
Max Torque
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0000
h
Firmware version
FIR-v1426
Change history
Description
This object is calculated as thousandths of the torque, e.g., the value "500" means "50%" of the rated
torque; "1100" is equivalent to 110%. The rated torque corresponds to the rated current in object
203B
h
:01.
The target torque may not exceed the peak torque (proportional to the peak current in 2031
h
).
6074h Torque Demand
Function
Current torque set value requested by the ramp generator in tenths of a percent of the nominal torque
for the internal controller.
Object description
Index
6074
h
Object name
Torque Demand
Version: 1.0.1 / FIR-v1748
245