Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
PDO mapping
no
Allowed values
Preset value
02
h
Subindex
01
h
Name
DeltaSpeed
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
000001F4
h
Subindex
02
h
Name
DeltaTime
Data type
UNSIGNED16
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0001
h
Description
The acceleration is specified as a fraction in user-defined units:
Speed change per change in time.
Subindex 01
h
: Contains the change in speed.
Subindex 02
h
: Contains the change in time.
6049h Vl Velocity Deceleration
Function
Sets the deceleration (deceleration ramp) in Velocity Mode (see Velocity).
Object description
Index
6049
h
Object name
Vl Velocity Deceleration
Object Code
RECORD
Data type
VELOCITY_ACCELERATION_DECELERATION
Savable
yes, category: application
Firmware version
FIR-v1426
Change history
Version: 1.0.1 / FIR-v1748
230