9 Description of the object dictionary
Number
dec
hex
Signal source
196
C4
Inverted encoder input "A"
197
C5
Inverted encoder input "B"
198
C6
Inverted encoder input "Index"
199
C7
Inverted USB power signal
200
C8
"Ethernet active" inverted status
201
C9
Inverted DIP switch 1
202
CA
Inverted DIP switch 2
203
CB
Inverted DIP switch 3
204
CC
Inverted DIP switch 4
205
CD
Inverted DIP switch 5
206
CE
Inverted DIP switch 6
207
CF
Inverted DIP switch 7
208
D0
Inverted DIP switch 8
3250h Digital Outputs Control
Function
This object can be used to control the digital outputs as described in chapter " Digital inputs and outputs".
The following applies for all subindices:
●
Bits 0 to 15 control the special functions.
●
Bits 16 to 31 control the level of the outputs.
Object description
Index
3250
h
Object name
Digital Outputs Control
Object Code
ARRAY
Data type
UNSIGNED32
Savable
yes, category: application
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1426: Subindex 01
h
: "Name" entry changed
from "Special Function Disable" to "Special Function Enable"
Firmware version FIR-v1446: "Name" entry changed from "Special
Function Enable" to "No Function".
Firmware version FIR-v1512: The number of entries was changed
from 6 to 9.
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
Version: 2.0.1 / FIR-v1650