![NANOTEC PD4-C Technical Manual Download Page 137](http://html1.mh-extra.com/html/nanotec/pd4-c/pd4-c_technical-manual_3241514137.webp)
9 Description of the object dictionary
Allowed values
Preset value
0000
h
Firmware version
FIR-v1540
Change history
Firmware version FIR-v1614: "Savable" entry changed from "no" to
"yes, category: application".
2050h Encoder Alignment
Function
This value specifies the offset between the index of the encoder and the electric field.
Object description
Index
2050
h
Object name
Encoder Alignment
Object Code
VARIABLE
Data type
INTEGER32
Savable
yes, category: tuning
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1540: "Savable" entry changed from "no" to
"yes, category: tuning".
Description
The exact determination is only possible via auto setup . The presence of this value is necessary for closed
loop mode with encoder.
2051h Encoder Optimization
Function
Contains compensation values for achieving better runout in closed loop mode.
Object description
Index
2051
h
Object name
Encoder Optimization
Object Code
ARRAY
Data type
INTEGER32
Savable
yes, category: tuning
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1540: "Savable" entry changed from "no" to
"yes, category: tuning".
Version: 2.0.1 / FIR-v1650