![NANOTEC ELECTRONIC N5 Technical Manual Download Page 319](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153319.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
02
h
Subindex
01
h
Name
Min Position Range Limit
Data type
INTEGER32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Subindex
02
h
Name
Max Position Range Limit
Data type
INTEGER32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Description
If this range is exceeded or not reached, an overflow occurs. To prevent this overflow, limit values for
the target position can be set in object 607D
h
("Software Position Limit").
607Ch Home Offset
Function
Specifies the difference between the zero position of the controller and the reference point of the
machine in user-defined units.
Object description
Index
607C
h
Object name
Home Offset
Object Code
VARIABLE
Data type
INTEGER32
Version: 2.0.1 / FIR-v1650
319