10 Description of the object dictionary
Allowed values
Preset value
0001
h
Description
The deceleration is specified as a fraction in user-defined units:
Speed change per change in time.
Subindex 01
h
: Contains the change in speed.
Subindex 02
h
: Contains the change in time.
604Ah Vl Velocity Quick Stop
Function
Object description
Index
604A
h
Object name
Vl Velocity Quick Stop
Object Code
RECORD
Data type
VELOCITY_ACCELERATION_DECELERATION
Savable
yes, category: application
Firmware version
FIR-v1426
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
02
h
Subindex
01
h
Name
DeltaSpeed
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00001388
h
Subindex
02
h
Version: 2.0.1 / FIR-v1650