Technical Manual N5 (CANopen)
10 Description of the object dictionary
SYNC (synchronization)
Value = "1": Controller is in sync with the fieldbus; value = "0": Controller is not in sync with the
fieldbus
REM (Remote)
Remote (value of the bit is always "1")
TARG
Target reached
ILA (Internal Limit Reached)
Limit exceeded
OMS (Operation Mode Specific)
Meaning is dependent on the selected operating mode
CLA (Closed Loop Available)
Value = "1": Auto setup was successful and encoder index seen: closed loop mode possible
Listed in the following table are the bit masks that break down the state of the controller.
Statusword (6041
h
)
State
xxxx xxxx x0xx 0000
Not ready to switch on
xxxx xxxx x1xx 0000
Switch on disabled
xxxx xxxx x01x 0001
Ready to switch on
xxxx xxxx x01x 0011
Switched on
xxxx xxxx x01x 0111
Operation enabled
xxxx xxxx x00x 0111
Quick stop active
xxxx xxxx x0xx 1111
Fault reaction active
xxxx xxxx x0xx 1000
Fault
6042h Vl Target Velocity
Function
Specifies the target speed in user-defined units.
Object description
Index
6042
h
Object name
Vl Target Velocity
Object Code
VARIABLE
Data type
INTEGER16
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00C8
h
Firmware version
FIR-v1426
Version: 2.0.1 / FIR-v1650