![NANOTEC ELECTRONIC N5 Technical Manual Download Page 186](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153186.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Name
Event Timer
Data type
UNSIGNED16
Access
read / write
PDO mapping
no
Allowed values
Preset value
0000
h
Description
Subindex 01
h
(COB-ID): The COB-ID is stored here.
Subindex 02
h
(transmission type): A number is stored in this subindex that defines the time at which
the received data become valid.
Subindex 3 (inhibit time): This can be used to set a time in milliseconds that must elapse after the
sending of a PDO before the PDO is sent another time. This time only applies for asynchronous PDOs.
Subindex 4 (compatibility entry): This subindex has no function and exists only for compatibility
reasons.
Subindex 5 (event timer): This time (in ms) can be used to trigger an Event which handles the copying
of the data and the sending of the PDO.
For details, see chapter on configuring the TX-PDO mapping.
1805h Transmit PDO 6 Communication Parameter
Function
Contains the communication parameters for the sending-side mapping (TX-PDO) 6. See chapter
Process Data Object (PDO).
Object description
Index
1805
h
Object name
Transmit PDO 6 Communication Parameter
Object Code
RECORD
Data type
PDO_COMMUNICATION_PARAMETER
Savable
yes, category: communication
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1614
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
Version: 2.0.1 / FIR-v1650