![Nanometrics Trillium Compact User Manual Download Page 20](http://html1.mh-extra.com/html/nanometrics/trillium-compact/trillium-compact_user-manual_3226289020.webp)
l
For extremely low temperature deployments, (below -40ºC) use Molykote 33 or Uniflor
8911 grease
To apply the grease:
1. Apply a layer of grease to the seismometer end of the cable connector as follows:
1. If the connector is dry, apply a layer of grease approximately 2 mm thick.
2. If the connector is already wet (for example, in the field), apply a layer of grease
approximately 8 mm thick.
2. To distribute the grease into the socket holes and onto the connector prongs, push
together the two ends of the connector, then pull them apart again to verify that the
grease has been distributed sufficiently.
3. Once the grease distribution has been verified, reconnect the ends and tighten the red
locking sleeves to prevent the connectors from coming apart.
For more information, see the video,
SubConn ® greasing and mating above water (dry mate)
,
published by MacArtneyGroup (2013). Retrieved from
https://www.youtube.com/watch?v=Vp_cbGtSsXI
2.5 Connecting the Centaur digital recorder and the Trillium
Compact
Use the guidelines in this section to connect the Centaur digital recorder and the Trillium
Compact.
1. Ground the system using the guidelines in
"Grounding guidelines " on page 89
2. Power up the digital recorder. You can continue with the steps in this procedure while
the digital recorder is booting up.
3. Using the appropriate seismometer to digitizer cable, see
, attach the seismometer connector to the Trillium Compact making sure that
the guides on the cable connector align with the notches on the Trillium Compact.
4. Attach the other end of the cable to the digital recorder, making sure that the guides on
the cable connector align with the notches on the digital recorder
Once powered up, the digital recorder will provide pass-through power to the seismometer as
well as feedback regarding seismometer operation.
Chapter 2 - Installing a Trillium Compact Posthole Seismometer
16889R10 • 2020-11-12
Page 20