These luminaires are suitable for humid, indoor environments. Do not install your 
luminaires in wet or outdoor environments. Do not operate these luminaires close to 
combustible materials. The light bar and track will get hot during operation. Do not touch 
the bar or track during or right after operation. Make sure the power cord does not touch 
any hot part of the luminaire. Make sure the light bar is clean and inserted correctly. A 
normal operating environment temperature should be below 104°F. Exceeding the 
maximum environmental temperature will stress electronic components, which will lead 
to shorter lifetime and decreased reliability.

Our fixture comes with a heat sink rather than other cooling components, dissipating 
heat effectively and allowing maximum heat conductivity during the operation.

This model is compatible with SLC controller & DTU NCCS-APP-2.0 (the “DTU”). 
Insert telephone wire into the jack of the track and SLC controller / DTU, and then 
Dimming function on the luminaire will be enabled. 

● Maximum of 120 units can be controlled.
● Simulate sunrise and sunset for dimming.
● Turn off the device automatically with time and temperature setting.

In & Out jacks included on the Light Track allows for multi-fixtures connected in parallel.

●  Comply with local installation regulations.
●  Store the fixture in a dry and clean environment, with an ambient temperature of -10°C 

~ 50°C and ambient humidity of less than 90% RH. It is recommended that the fixture 
doesn't sit unused for longer than six months. If it has sat unused for longer than six 
months, please test to ensure fixture is functioning at 100%.

●  Please  keep  products  safe.  Avoid  mechanical  pressure,  excessive  vibration  and 

dropping the unit during the process of assembly to protect the light bar and track.

●  Keep away from water, oil and organic solvent, or it will decrease the efficacy and have 

the potential risk of electric leakage.

●  All equipment, devices and machines shall be effectively grounded.
●  Regularly check and clean the dust from the heatsink and LED array.

    1. Disconnect from power supply before general care.
    2. Remove the dust from the light bar using low-pressure compressed air.
    3. Clean the diode array with a soft cloth preventing it from being scratched.
   4. Be sure not to touch the diode with your bare hands, even after the luminaire is 

disconnected from power supply.

●  It is recommended that you contact a licensed electrician or an expert if any of the 

    following take place:
    1. The cable or the plug has been damaged. 
    2. The unit has been exposed to rain.
    3. Significant changes in the unit performance.
    4. Dropped fixture or light bar and bent corner of its enclosure.

● There are no serviceable parts inside the luminaire. Opening the luminaire will void 

warranty.

Nanolux warrants manufacturing defects of this product if used under normal operating 
conditions for a period of three (3) years from the original date of purchase. If the product 
shows manufacturing defects within this period and that defect is not due to user error or
improper use, Nanolux shall, at its discretion, either replace or repair the product using 
suitably new or refurbished parts. For service return the product to your shop with the 
original sales receipt.

SCOPE OF USE AND MAINTENANCE

TROUBLESHOOTING

ALWAYS COMPLY WITH LOCAL 

INSTALLATION REGULATIONS AND CODES

0-10V DIMMING

Problem

One or more 

fixtures are 

completely off.

Disconnect from power source. 

Broken cable or wire connecting

controller to fixture or wire

connecting fixture to fixture.
The power supply settings do 

not match with local AC 

voltage and frequency.

Make sure power is on and 

cables are plugged in.

Dimming

failure

LED will not 

come on.

Probable cause(s)

Possible fixes or 

corrective maintenance

CAUTION:  

After installation, verify installation was a success by cycling the lights on/off a few times, 
by setting 'over temperature shut down' to a low value like 85°F, and rubbing the 
temperature probe with your fingers, tricking the controller /DTU into an over temperature 
condition and shutting the lights off. Then leave the probe alone, and after recommended 
10-15 minutes the controller /DTU should turn all the lights back on.

 
For detailed instructions, please refer to SLC & DTU NCCS-APP-2.0 operating manual.

Method#3: wall-mounted installation

1. Only mount the product on a solid surface. 
2. Pre-measure the holes for mounting first.
3. Drill two holes on the wall, then put the mounting hook into installation holes.
4. Insert and tighten the screw to secure the mounting hook.
5. Slide the light bar into the mounting hooks.

Repair or replace any

damaged cables if necessary.

Disconnect fixture from the 

power supply. Check settings 

and correct if necessary.