Before starting assembly, please read
the following:
NSS 100 is a single-use product. It should be
replaced as directed to ensure its vital
environmental and legally protective functions are
performed correctly.
NSS 100 has been designed to clean condensate from
a compressor system of up to 102 m
3
h to better than
10 ppm oil-in-water; suitable for discharge to a sewer.
NOTE: This is generally well below the
accepted level, but it is the users responsibility to
ensure compliance with local regulations.
Top Inlet Port
The unit comes shipped with a
6mm inlet port as standard
1
Other size inlet ports are available as shown above.
Please specify when ordering.
Installation
Fix the wall plate vertically on a
suitable wall or the compressor
cabinet. Isolate the compressor
and look out for cables and pipes
when drilling.
Slide the NSS 100 on to the
plate, with the venting flutes at
the top.
Connect all drain points, insert
tube into push fitting in the inlet
(top).
6 mm tube for metric
¼” tube for imperial
Connect tube into outlet fitting
and feed to drain (side). Ensure
a steady fall from outlet point to
drain with no kinks or tight
bends.
10 mm tube for metric
a
” tube for imperial
IMPORTANT - Always use an automatic drain.
Set timers to short open periods of one second or less.
NEVER
use manual drains which could flood the separator, forcing partially treated or untreated condensate to be discharged.
2
3
4
5
6
inlet
anti-siphon vent
(do NOT block)
outlet
NSS 100
single use condensate cleaner
Installation Manual
8mm
1/4”
5/16”