Adding to a Zigbee Network
F
Zigbee Configuration Introduction
Select Network Set on Home Interface to enter into Zigbee network management interface as follow:
Zigbee Interface
The thermostat provides 3 zigbee application endpoints:
Operate your Zigbee gateway to add device, select “Add”, then short press button , the device will search network
and try to join, “Status” will show “Inclusion...”. If there is no response from a gateway, or adding failed, “Status” will
show “Fail”. If added successfully, “Status” will show “Inclusion OK” and device ID.
Removing from a Zigbee Network
Operate your Zigbee gateway to remove device, Select “Remove”, then short press button , the device will send out
removing request, “Status” will show “Exclusion...”. If there is no response from a gateway, or removing failed, “Status”
will show “Fail”. If removed successfully, “Status” will show “Exclusion OK” and device ID will be showed as 0.
The device will be removed from the network and all parameters will be restored to factory default setting, all
bindings will be cleared.
Factory Reset (Reset)
Factory resetting will remove the device from Zigbee network and all parameters will be restored to factory default
setting, all bindings will be cleared.
Select “Reset”, then short press button , the device will start reset, “Status” will show “Reset...”. If exclusion failed,
“Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”.
F
F
Configure Device Operation Mode through Zigbee
5.1 Application Endpoint #0 –ZigBee Device Object
• Application profile Id 0x0000
• Application device Id 0x0000
• Supports all mandatory clusters
Since Zigbee does not have away mode, the attribute Occupancy (occupied or unoccupied) of Thermostat (0x0201)
and attribute Occupancy of received OccupancySensing (0x0406) are required to judge whether it is away mode.
1) if the device receives other devices’ or the gateway’s report: the Bit 0 of the value of attribute Occupancy (0x0000) of
OccupancySensing Cluster (0x0406) is 1, which means occupied, then the operation mode of the thermostat, the
attribute SystemMode(0x001c)=0x04(heat) of Thermostat (0x0201), meanwhile the value of attribute Occupancy
(0x0002) of Thermostat (0x0201) is 0. It means the Away Mode is activated, and the thermostat UI will display.
2) if the gateway send command to modify the attribute SystemMode(0x001c) of Thermostat (0x0201), the thermostat
will quit Away Mode. Meanwhile the value of attribute Occupancy (0x0002) of Thermostat (0x0201) is 1.
3) The proprietary attribute 0x2002(Manufacturer Code=0x1224) of the cluster 0x0201 can be modified to configure
whether it is away mode or at home.
Note: Away Mode uses attribute UnOccupiedHeatingSetpoint to set temperature.
Other modes uses attribute OccupiedHeatingSetpoint to set temperature.
Endpoint
Profile
Application
1(0x01)
0(0x00)
242(0xF2)
2(0x02)
0xA1E0(GP)
0x0104(HA)
0x0104(HA)
0x0000(ZDP)
ZigBee Device Object (ZDO) – standard management features
Device ID is 0x0007(OTA).
Device ID is 0x0301(Thermostat ).
Device ID is 0x0021(GreenPower).