0x050B
int16S ,
reportable
read-only
Single phase valid power, unit is W
ActivePower
0x0600
int16U,
read-only
ACVoltageMultiplier
0x0601
int16U,
read-only
ACVoltageDivisor
Used together with above attributes, the real displayed voltage =
RMSVoltage* ACVoltageMultiplier
/ ACVoltageDivisor
0x0602
int16U,
read-only
ACCurrentMultiplier
0x0603
int16U,
read-only
ACCurrentDivisor
/ ACCurrentDivisor
Used together with above attributes, the real displayed current = RMSCurrent
* ACCurrentMultiplier
0x0800
int16U,
Specifies which configurable alarms may be generated, only
Bit1: Current Overload is set, if set=0, then ACCurrentOverload=0, over
current will not be detected
ACAlarmsMask
0x0802
int16S ,
reportable
read-only
ACCurrentOverload
Alarms when the current is over a certain value, 0, 10-16, unit is A, for the
unit please refer to RMSCurrent, ACCurrentMultiplier, ACCurrent Divisor
Proprietary Attributes:
Attribute
0x0000
Type
Int8u,
reportable
Manufacturer code
0x1224
Description
OverCurrent
Over current value set by the user, range is 0, 10-16,
ACCurrentOverload will change spontaneously if this
value is modified.
5.2.7 Alarm-0x0009(Server)
The Alarm Server cluster can generate the following commands
Please set a valid value for ACAlarmsMask of Electrical Measurement.
The Time cluster is a general cluster for time it is based on a UTC time in seconds since 0 hrs 0 mins 0 sec on
1st January 2000. Refer to [Z2] for ZigBee specification of the time cluster.
If the device has bound TIME cluster, then the device will acquire the value of Local Time (0x0007)
spontaneously.
5.2.8 Time-0x000A(server)
The metering device will use this clusters as a client – provided that a suitable Time Server is available on the
network (most likely on the Gateway/concentrator)
0x00
Room air temperature over heat, not alarm code
CmdID
Description
CmdID
Description
0x00
Alarm:
The alarm code of Electrical Measurement is 0,
Proprietary command,
Manufacturer code=0x1224