3.3 mains supply

Where fused plugs are used 13 amp fuses should be fitted.

Fuses of a lower rating will fail after a period of use.

A hi-fi system usually shares a mains circuit with other

household equipment some of which can cause distortion

of the mains waveform. In some Naim equipment such

distortion can lead to a mechanical hum from the

transformers. The hum is not transmitted through the

speakers and has no effect on the performance of the

system but is purely local to the transformer itself. A

separate fused mains circuit (like that reserved for electric

cookers) may reduce transformer hum. Such a circuit

(ideally with a 30 or 45 Amp rating) will also have a lower

impedance, supply cleaner power, and consequently

improve system performance.

Do not wire voltage dependent resistors or noise

suppressors into mains plugs. They degrade the mains

supply and the sound.

3.4 siting the equipment

Power supplies and amplifiers should be located a

reasonable distance away from other equipment. This

separation will stop transformer radiation causing hum

audible from the loudspeakers. The maximum separation

distance for connected equipment is that allowed by the

standard interconnect lead.

Some Naim equipment is extremely heavy. Ensure that your

equipment rack or table can easily support the weight and

is stable.

3.5 if you have a problem

Legal consumer protection varies from country to country.

In most territories a dealer must be prepared to take back

any Naim equipment he has sold you if he cannot make it

work to your satisfaction in your own home. A problem may

be due to a fault in any part of the system or its

installation so it is essential to make full use of your local

dealer’s diagnostic skills on site. Please contact your local

distributor, or Naim at the address in the back of this

manual, if any difficulties cannot be resolved. Some Naim

equipment is made in special versions for different

territories and this makes it impracticable to arrange

international guarantees. Please establish the guarantee

arrangements with your own dealer at the time of sale. We

are always available to offer help and advice.

It is essential that repairs and updates are only carried out

by an authorised Naim dealer, or at the factory by Naim

itself. Many components are made, tested or matched

specially for Naim and appropriate replacements are often

unobtainable from non-specialist sources.

4 Warnings

Naim equipment is designed to offer the finest sound

quality that can be achieved avoiding compromise

wherever possible. This can lead to circumstances that

may be unfamiliar. The material that follows contains

advice specifically related to Naim equipment as well as

more general warnings about the use of domestic audio

products. Please read it carefully.

The transformers in Naim power amplifiers and power

supplies may sometimes make a mechanical noise caused

by distortion of the mains waveform. Naim transformers are

large in size and have heavy gauge secondary windings

making them relatively sensitive to such distortion. A

separate mains circuit for your hi-fi system may reduce the

effect while also giving an overall improvement in sound

quality. It may be necessary however to take account of

mechanical transformer noise when siting your equipment.

IMPORTANT

In order to comply with
current European safety
regulations it is essential
that the Naim loudspeaker
connectors supplied with
amplifiers and loudspeakers
are used.

Do not under any
circumstances allow anyone
to modify your Naim
equipment without first
checking with the factory,
your dealer, or your
distributor. Unauthorised
modifications will invalidate
your guarantee.

For your own safety do not
under any circumstances
open Naim equipment
without first disconnecting
the mains.

The following label is
attached to all mains
powered equipment:

W A R N I N G

THIS APPARATUS

MUST BE EARTHED

Introduction

Summary of Contents for NA-P 200 - AMPLIFIER

Page 1: ...O W N E R S M A N U A L Power amplifiers NAP 500 NAP 300 NAP 250 NAP V145 NAP 200 NAP 150 NAP V175 I S S U E 1 W O R L D C L A S S H I F I ...

Page 2: ...u even if you live outside their immediate vicinity Your dealer is responsible for making sure that the system sounds exactly as it should and information given here is not intended to reduce this responsibility in any way Introduction Naim Audio products are always conceived with performance as the top priority and careful installation will help ensure that their full potential is achieved This m...

Page 3: ...t be resolved Some Naim equipment is made in special versions for different territories and this makes it impracticable to arrange international guarantees Please establish the guarantee arrangements with your own dealer at the time of sale We are always available to offer help and advice It is essential that repairs and updates are only carried out by an authorised Naim dealer or at the factory b...

Page 4: ...ol or coloured green or green and yellow The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter N or coloured black The wire which is coloured BROWN must be connected to the terminal in the plug which is marked with the letter L or coloured red 5 2 non rewireable mains plugs If a non rewireable plug is cut from a mains lead for whatever purpos...

Page 5: ... necessary to switch the amplifier off but it may be advisable to mute the preamplifier or turn the volume down to avoid surprises when it comes back on OPERATION OF THE AMPLIFIER S THERMAL PROTECTION SUGGESTS PROLONGED USE AT TOO HIGH A VOLUME LEVEL YOUR LOUDSPEAKERS MAY BE AT RISK IF THIS IS THE CASE THE VOLUME SHOULD BE REDUCED NAP 500 6 Installation and Operation The NAP 500 and NA PS500 shoul...

Page 6: ... Power Supply ch1 ve ve nc nc ch2 mains in 7 2 Specifications NAP 500 NA PS500 Power Output Continuous 8 ohms 140 Watts per channel Transient 700VA Quiescent Power Consumption 60VA Voltage Gain 29dB Input Impedance 18 kilohms Frequency response 3dB 1 5Hz and 100kHz Mains Supply 100V 115V 230V 50 60Hz Case size H x W x D NAP 500 160 x 432 x 375mm NA PS500 87 x 432 x 314mm Weight NAP 500 25 0kg NA P...

Page 7: ...the signal negative of the whole system should be connected to the mains earth ground in one place This should be the primary signal source 8 2 protection notes In the NAP 300 the fan speed is increased in response to an increase in amplifier dissipation If the amplifier reaches 70 C due to prolonged running at high level or to airflow being blocked the output will be interrupted and the fan will ...

Page 8: ...Input Socket 1 Input Socket 2 ch1 ve ve nc nc ch2 9 2 Specifications NAP 300 NA PS300 Power Output Continuous 8 ohms 90 Watts per channel Transient 500VA Quiescent Power Consumption 27VA Voltage Gain 29dB Input Impedance 18 kilohms Frequency response 3dB 2Hz and 70kHz Mains Supply 100V 115V 230V 50 60Hz Case size H x W x D NAP 300 87 x 432 x 314mm NA PS300 87 x 432 x 314mm Weight NAP 300 10 7kg NA...

Page 9: ...IGH A VOLUME LEVEL YOUR LOUDSPEAKERS MAY BE AT RISK IF THIS IS THE CASE THE VOLUME SHOULD BE REDUCED 10 3 loudspeaker cable and connectors Only Naim Audio speaker cable should be used to connect a loudspeaker to the output of the NAP 250 Custom Naim Audio loudspeaker connectors are supplied to make the connection IN ORDER TO COMPLY WITH CURRENT EUROPEAN SAFETY REGULATIONS IT IS ESSENTIAL THAT THES...

Page 10: ...put Continuous 8 ohms 80 Watts per channel Transient 400 VA Quiescent Power Consumption 25VA Voltage Gain 29dB Input Impedance 18 kilohms Frequency response 3dB 2Hz and 65kHz Case size H x W x D 87 x 432 x 314mm Mains Supply 100V 115V 230V 50 60Hz Weight 15 8kg left speaker ch1 right speaker ch2 to preamplifier power supply ...

Page 11: ...SK IF THIS IS THE CASE THE VOLUME SHOULD BE REDUCED 12 3 loudspeaker cable and connectors Only Naim Audio speaker cable should be used to connect a loudspeaker to the output of the NAP V145 Custom Naim Audio loudspeaker connectors are supplied to make the connection IN ORDER TO COMPLY WITH CURRENT EUROPEAN SAFETY REGULATIONS IT IS ESSENTIAL THAT THESE ARE USED DAMAGE TO THE AMPLIFIER MAY RESULT IF...

Page 12: ...P V145 Power Output Continuous 8 ohms 80 Watts Transient 400 VA Quiescent Power Consumption 15VA Voltage Gain 29dB Input Impedance 18 kilohms Frequency response 3dB 2Hz and 65kHz Case size H x W x D 87 x 432 x 314mm Mains Supply 100V 115V 230V 50 60Hz Weight 15 8kg speaker output to preamplifier power supply ...

Page 13: ...and connectors Only Naim Audio speaker cable should be used to connect a loudspeaker to the output of the amplifier Custom Naim Audio loudspeaker connectors are supplied to make the connection IN ORDER TO COMPLY WITH CURRENT EUROPEAN SAFETY REGULATIONS IT IS ESSENTIAL THAT THESE ARE USED DAMAGE TO THE AMPLIFIER MAY RESULT IF HIGH DEFINITION CABLE OR ANY OTHER SPECIAL CABLE IS USED TO CONNECT THE L...

Page 14: ...ze H x W x D 87 x 432 x 314mm Mains Supply 100V 115V 230V 50 60Hz Weight 11 6kg 15 4 Specifications NAP 150 Power Output Continuous 8 ohms 50 Watts per channel Transient 250 VA Quiescent Power Consumption 10VA Voltage Gain 29dB Input Impedance 18 kilohms Frequency response 3dB 3Hz and 50kHz Power Supply Output 24V 0 3A Case size H x W x D 69 4 x 432 x 301mm Mains Supply 100V 115V 230V 50 60Hz Weig...

Page 15: ...Only Naim Audio speaker cable should be used to connect a loudspeaker to the output of the NAP V175 Custom Naim Audio loudspeaker connectors are supplied to make the connection IN ORDER TO COMPLY WITH CURRENT EUROPEAN SAFETY REGULATIONS IT IS ESSENTIAL THAT THESE ARE USED DAMAGE TO THE AMPLIFIER MAY RESULT IF HIGH DEFINITION CABLE OR ANY OTHER SPECIAL CABLE IS USED TO CONNECT THE LOUDSPEAKERS 16 I...

Page 16: ...r 17 2 Specifications NAP V175 Power Output Continuous 8 ohms 50 Watts per channel Quiescent Power Consumption 13VA Channels Three Voltage Gain 29dB Input Impedance 18 kilohms Frequency response 3dB 3Hz and 50kHz Case size H x W x D 69 4 x 432 x 301mm Mains Supply 100V 115V 230V 50 60Hz Weight 7 9kg left speaker ch1 centre speaker right speaker ch2 ...

Page 17: ...ound and television broadcast receivers and associated equipment Immunity Tested to EN55020 Electromagnetic immunity of broadcast receivers and associated equipment In accordance with CISPR 16 1 Radio disturbance and immunity measuring apparatus CISPR 16 2 Methods of measurement of disturbances and immunity IEC 801 2 8KV air gap 4KV contact performance criterion B IEC 801 3 3V m 20dB performance c...

Page 18: ...Part No OWMPA 12 001 0038 DRG No NA202001 400 Naim Audio Limited Southampton Road Salisbury England SP1 2LN Telephone 44 0 1722 332266 Fax 44 0 1722 412034 www naim audio com ...

Reviews: