Nahita blue LJN006 Operation And Maintenance Manual Download Page 1

English 

User’s manual for LJN006 

 

Version 1, July 2023 

LJN006 

Operation and Maintenance Manual 

    

       

 

 

 

 

 

 

 

 

Safety rules

 

  For safety, please read the operation manual carefully before starting operation! 

  Parts subject to heat, humidity and biological changes will cause functional 

degradation and even loss of safety leading to accidents!

 

Summary of Contents for blue LJN006

Page 1: ...Operation and Maintenance Manual Safety rules For safety please read the operation manual carefully before starting operation Parts subject to heat humidity and biological changes will cause function...

Page 2: ...rd 3 Instrumentuse environment 3 Safety Tips 4 product brief 5 Product model and its main technical parameters 6 Introduction to the appearance and functions 7 8 Operating Instructions 8 9 Maintenance...

Page 3: ...mponents Indoor use Altitude 2000m The suitable temperature range for instrument operation is 5 40 The applicable relative humidity range for instrument operation is 80 Scope of application of instrum...

Page 4: ...onment you must comply with all safety instructions in this user manual In addition to recognized professional rules regarding accident prevention environmental protection and safety and occupation in...

Page 5: ...n of electrophoresis gel fixation dyeing and development during Silver nitrate dyeing The development and fixation of X ray films in autoradiography experiments Further treatment of the cellulose memb...

Page 6: ...ontrol mode PWM stepless speed regulation Operation mode Continuous Jog Programmable parameter t 10 built in Stored procedure Oscillation mode circumference Circumferential diameter 10mm Time function...

Page 7: ...arance and Function of the Bleaching Shaker A Operation panel B Container tray C Rubber feet D Power switch The above picture shows the LJN006 decolorization shaker exterior schematic diagram 1 The ab...

Page 8: ...nu key is used to select speed and time parameters 4 Dynamic symbol for operation 5 Speed display area unit r min 6 Time display area in minutes per second 7 Stored procedure number display area 0 10...

Page 9: ...rance schematic diagram 1 is turned on by turning one to the ON position When O is turned to the OFF position the power is turned off 2 The maximum speed limit of the instrument is 300rpm and the step...

Page 10: ...lease stop using and contact the production unit 5 3 When cleaning the tray please use neutral detergent to wet the sponge or cotton cloth and then use distilled water to wash the detergent Do not spr...

Page 11: ...terference or too fast acceleration Check the speed measurement line and lower the acceleration gear E7 No speed measurement No speed measurement signal input There are many reasons for generating no...

Page 12: ...main engine 1 2 Certificate of Conformity 1 3 Quality Assurance Page 1 4 Operating Instructions 1 5 Power cord 1 6 tray 1 When unpacking please check in a timely manner If there are any discrepancies...