NDRA91-92
Manual
Operating conditions
NADO
Page 17
Seite 17
3
Operating conditions
3.1
Electrical installation conditions
Use only a supply voltage of 10 V ... 30 V DC (direct current voltage). For using
the heating, direct current voltage of 24 V is recommended.
The limit values for the input voltage have to be observed. Do not
wire inputs as outputs.
All outputs are short circuit proof.
The housing is galvanically separated from the sensor electronics assembly.
The interference resistance at electrostatic discharge (ESD) is 4 kV according to
EN 61326-1.
Table 1 : Electrical installation conditions
Electrical installation conditions
Supply voltage
10 V ... 30 V DC (direct current voltage)
3
Power consumption
< 5 W (without heating)
11.5 W (with heating, 24 V)
3.2
Operating and storage conditions
Operating temperature -40 °C … +60 °C
Stroage temperature
-40 °C ... +70 °C
Air humidity
15 % ... 90 % not condensing
The mentioned
operating and storage conditions
have to be
observed. When the operating temperatures exceed the permitted
values, the device will not be switched off automatically. The
continuous overheating of the device will reduce the lifetime of the
laser diode.
3
For using the heating, direct current voltage of 24 V is recommended.