10
Reset to default configuration
Host trigger mode setting step
:
1
、
wake up operation: Send 0x00 first, then send effective instruction after 50ms,
(
factory default is power saving mode
)
2
、
start scan:04 E4 04 00 FF 14
3
、
end scan:04 E5 04 00 FF 13
4
、
after end scan, scanner module time-out in 800ms without working
remark
:
If you want to omit step 1 and 4, please change power mode to continuous power mode
2.2.5 scan time interval setting of the same barcode (continuous scanning mode)
When the scanner is in
continuous scanning mode
, this re-scanning setting will come out the result
with one barcode when you scan two identical barcodes, which reduce the risks of scan the identical
barcodes. The interval time is in the range of 0.0 second to 9.9 second, the smallest unit is 0.1 second. If
you want to set the interval time, scan the below barcode first, then scan two numbers as the interval time.
Use 0 to make up three numbers if the time you want to set less than
two numbers.
For example, you
want to set 0.5 second as interval time, scan the barcode below then scan”0””5” at the appendix. If you
want to change or cancel one incorrect setting, scan the “
cancel setting
” in the appendix.
2.2.6
scan time interval setting of the same barcode (Auto mode)
When the scanner is in
auto mode
, this re-scanning setting will come out the result with one barcode
when you scan two identical barcodes, which reduce the risks of scan the identical barcodes. The interval
time is in the range of 0.0 second to 9.9 second, the smallest unit is 0.1 second. If you want to set the
interval time, scan the below barcode first, then scan two numbers as the interval time. Use 0 to make up
three numbers if the time you want to set less than two numbers. For example, you want to set 0.5 second
as interval time, scan the
barcode below then scan”0””5” at the appendix. If you want to change or cancel
one incorrect setting, scan the “cancel setting” in the appendix.
2.2.7 Data uploading format
Data uploading format: b suffix character
。
Cancel suffix character
Re-scanning time (default: 1.0 second)
CRLF
Re-scanning time (default: 1.5 second)