6.2Setting for
6-4
6.2.2
Setting for the PROFINET Safety
Channel settings
1
In [3 Fieldbus] screen, align the cursor with the channel where PROFINET safety
is selected and press <Refer>.
>> Following screen is displayed.
2
Set the respective parameters.
Item
Description
Station Name
Input the station name for the concerned node.
Use alphanumeric (small letter) for the station name. Symbols,
signs, or marks cannot be used. The length is 240 letters at
maximum. This station name is used to identify the device on
the network. Plural nodes that have the same station name can
not be set in one network.
IP Address
Input the IP address for the concerned node.
IP address is used to identify the device on the network. Plural
nodes that have the same IP address can not be set in one
network.
Subnet mask
Input the subnet mask for the concerned node. Subnet mask
are values to manage a network by dividing it into several sub
network. In the same sub network, the all devices must have
the same setting values for this subnet mask.
Default gateway
Input the IP address of the Default gateway for the concerned
node.
This setting may not be necessary if a router does not exist in
the network. Please consult with the network administrator and
set this parameter if necessary.
INPUT BYTES
Set the INPUT BYTES from the Master device to this controller
(SLAVE device). 8 points are included in 1 byte. In this
PROFINET Safety function, these standard signals can be used
with the safety signals at the same time.
OUTPUT BYTES
Set the OUTPUT BYTES to the Master device from this
controller (SLAVE device). 8 points are included in 1 byte. In
this PROFINET Safety function, these standard signals can be
used with the safety signals at the same time.
Safety input bytes
This is the size of the safety input signals that is received by this
controller. 8 points are included in 1 byte. This parameter is
fixed to 8 bytes. This parameter cannot be changed.
Safety output bytes
This is the size of the safety output signals that are sent from
this controller. 8 points are included in 1 byte. This parameter is
fixed to 8 bytes. This parameter cannot be changed.
Summary of Contents for RMU20-20
Page 2: ......
Page 6: ...Contents 4 ...
Page 8: ......
Page 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Page 68: ...2 9 Enabling RMU 2 40 NOTE ...
Page 70: ......
Page 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Page 102: ......
Page 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Page 144: ......
Page 154: ...5 4Trouble shooting 5 10 NOTE ...
Page 156: ......
Page 166: ...6 4Trouble shooting 6 10 NOTE ...
Page 168: ......
Page 189: ......