Opus Control Wiring and Programming Installation Manual 

www.NabcoEntrances.com

P/N C-00139 

Rev 10-20-17

X

X

Error Specifications: 

•XThis screen will only display an Error Code in the event there is an Error. Otherwise this screen stays blank.

DN 1249

Type: 

GT710 Swing

Status: 

Slow Closing

Error: 

-----

Ac va on:  IN   EXT

Switch: 

LCHK   BCHK

Other: 

BA   6B   SLS

Keep Pushing Switch

=> Seˆ  ng Mode

UNIT SPECS

Recycle Warning!

Rotate

Dial

ERROR SPECS

Short

Push

FLASHING 

SCREEN

Long

Push

Recycle Warning!

Clear           Yes      No

ERROR SPECS

Rotate

Dial

Recycle Warning!

Clear                  No

ERROR SPECS

Yes

Short

Push

Figure 5 Example: Clear an Error Code for Recycle Warning 

X

X

 ANSI Specifications: 

•XDisplays the actual time of opening and closing of the door to help determine ANSI compliance.(Applies to swing 

doors only).

X

X

 Terminal Specifications: 

•XDisplays the current status of all of the Input/Output lines of the terminal strip.

SECTION 8.2: Level Two: Access Screen

Note: The “Activate Passcode” option is only displayed in the event “0045” had not already been entered.

DN 1713

Passcode

Stroke Learning

Yes   No

LEVEL 2

Rotate

Dial

Passcode

Stroke Learning

Yes   No

Passcode

Go to Se  ng Menu

Stroke Learning

 

Passcode

Go to Se  ng Menu

Stroke Learning

Go to Se  ng menu

Reset to Default Set

Yes

No

Passcode

Stroke Learning

Yes   No

Ac vate Passcode

Rotate

Dial

Rotate

Dial

Rotate

Dial

Figure 6 Level Two Screen

Attention:  To prevent tampering, a Universal Passcode (0045) has been programmed into all Opus Controls. 

This Passcode cannot be changed, but can be turned OFF and ON.

Attention:  Do Not activate Passcode (0045) until programming of the Opus Control is complete. Failure to do 

so, will force the User to enter (0045) each time a change is made. 

 8.2.1 Enter Passcode

Short 

Push

LEVEL 2

Reset to Default Set

If you don’t know

 the passcode,

 Keep Pushing Switch,

 Return to Normal mode

0

Short

Push

Reset to Default Set

If you don’t know

 the passcode,

 Keep Pushing Switch,

 Return to Normal mode

0 0

Short 

Push

Reset to Default Set

If you don’t know

 the passcode,

 Keep Pushing Switch,

 Return to Normal mode

0 0 0

Rotate

Dial

Reset to Default Set

If you don’t know

 the passcode,

 Keep Pushing Switch,

 Return to Normal mode

0 0 4

Short

Push

Reset to Default Set

If you don’t know

 the passcode,

 Keep Pushing Switch,

 Return to Normal mode

0 0 4 4

Rotate

Dial

0 0 4 5

Short

Push

Correct PassCode!

If you don’t know

 the password,

 Keep Pushing Switch,

 Return to Normal mode

0 0 4 5

Reset to Default Set

If you don’t know

 the passcode,

 Keep Pushing Switch,

 Return to Normal mode

DN 1715

Passcode

Stroke Learning

Yes   No

Ac… vate Passcode

Figure 7 Enter Passcode

Summary of Contents for Opus Control

Page 1: ...HAPTER 1 SAFETY 2 CHAPTER 2 SCOPE 3 SECTION 2 1 To the Installer 3 SECTION 2 2 Objective 3 CHAPTER 3 FEATURES 3 CHAPTER 4 SPECIFICATIONS 3 SECTION 4 1 General Specifications 3 SECTION 4 2 Electrical S...

Page 2: ...esult in seriouc personal or fatal injury When uncertain whether power supply is disconnected always verify using a voltmeter Do not place finger or uninsulated tools inside the electrical controller...

Page 3: ...nd Folding Doors X X Existing swing and folding doors using Analog Magnum or U01 U19 controls works with encoders or microswitches X X Existing sliding doors using U01 U19 controls Retrofit kits can b...

Page 4: ...er 24 VAC P N A 01185 The Opus Control must Not be used to output power to X X Magnetic Locks X X Electric Strikes To determine if an auxiliary power supply must be used add the total current draw of...

Page 5: ...of Header End Cap Attention Electrical circuit to Nabco operator must not be not shared with other equipment such as lighting cash registers or any device that might cause electrical interference on t...

Page 6: ...Communication 7 CN1 Power Connector 4 Rotary Dial 8 Fuse CHAPTER 7 THE ROTARY DIAL X X Push down on the Rotary Dial Long push 2 seconds to gain access to LCD Catagory Screens Short push under 2 second...

Page 7: ...lose Recycle Cnt Latest Recycle Posi on DN 1334 LEVEL 4 Push and Hold Rotary Dial 2 Sec Rotate Dial Rotate Dial Rotate Dial Short Push Figure 3 LCD Screen Transition SECTION 8 1 Level One Specificatio...

Page 8: ...oke Learning Go to Se ng menu Reset to Default Set Yes No Passcode Stroke Learning Yes No Ac vate Passcode Rotate Dial Rotate Dial Rotate Dial Figure 6 Level Two Screen Attention To prevent tampering...

Page 9: ...oints should happen Stroke Learning is also used to determine if an existing Operator Type is correct and or to determine if Handing is correct 1 Briefly press down on the Rotary Dial to select X X Ye...

Page 10: ...ly Open X X Slide Door 1 to 13 3 4 of Fully Open Close Speed 0 7 3 The higher the number the faster the Door closes Latch Check Speed 0 7 3 Sets door speed during latch check Latch Check Range 0 7 3 X...

Page 11: ...essure Manual Open Function No Action No Action Does nothing Push and Go P G Enables push and go Stop and Close S C Door pauses at open angle then closes Open Assist X X Assisted Power from motor when...

Page 12: ...X X Sensor Monitoring N C X X BEA Bodyguard Output Full Open X X Output doesn t change state X X Output changes when fully closed X X Output changes when door is closing X X Output changes when door...

Page 13: ...e to reduced open Emergency Close Forces the door to slowly close and lock if equipped Hold Open Mode Causes the door to hold open forever Input H Open Timer N A Same as Open Timer 0 thru 10 12 15 20...

Page 14: ...or slide doors it displays the position in inches from closed Test Open Tests Open Close door cycle while ignoring Safety Signals CHAPTER 9 COMMON PROGRAM ADJUSTMENTS SECTION 9 1 Stroke Learning UNIT...

Page 15: ...PECS Passcode Go to Se ng menu Stroke Learning Yes No Push and Hold Rotary Dial 2 Sec LEVEL 1 LEVEL 2 1 Rotate Dial to select Go to Se ng menu 2 Push Rotary Dial Se ng Category LEVEL 3 History Se ng P...

Page 16: ...Sequential activation Signal to open Signal to close 10 H Programmable input 11 M0 Mode 0 When grounded puts door into One Way Mode Hold Open when grounded with M1 12 M1 Mode 1 When grounded puts door...

Page 17: ...17 of 32 www NabcoEntrances com Opus Control Wiring and Programming Installation Manual Rev 10 20 17 P N C 00139 SECTION 10 2 Switches and Sensors with Monitoring DN 1895...

Page 18: ...ces Non Powered Activation Devices WARNING Total Power Consumption Of All Sensors And Powered Activation Devices Must Not Exceed 750 mA 7 6 5 4 3 2 1 3 2 4 All Device Outputs Must Be N O Dry Contact 7...

Page 19: ...3 2 1 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Exterior Push Plate Interior Push Plate COM N O COM N O All Devices Must Be N O Dry Contact Powered Activation Devices sensor card reader radio receiver etc Powe...

Page 20: ...or Slide Door Sidelite Sensor 7 Out1 Programmable Output 14 13 12 11 10 9 8 7 6 5 4 3 2 1 7 6 5 4 3 2 1 2 4 COM N O PWR PWR 1 Door Mounted Approach Side Sensor Door Mounted Swing Side Sensor CO O PWR...

Page 21: ...com Opus Control Wiring and Programming Installation Manual Rev 10 20 17 P N C 00139 SECTION 11 4 Safety with Monitoring Door Mounted Swing Side Sensor Door Mounted Approach Side Sensor Overhead Swing...

Page 22: ...4 13 12 11 10 9 8 7 6 5 4 3 2 1 Fail Secure Electric Strike Fail Secure Lock Shown Fail Safe and Mag Locks will use N C instead of N O Power Supply For Electric Strike N O COM N C Varistor MOV TVS DO...

Page 23: ...G TOTAL POWER CONSUMPTI ON OR ALL SENSORS MUST NOT EXCEED 750 mA ON OFF Hold Open Switch P N A 00805 COM N O PWR PWR COM N O PWR PWR COM N O PWR PWR COM N O PWR PWR va on Sensor Overhead Swing Side Se...

Page 24: ...24 of 32 Opus Control Wiring and Programming Installation Manual www NabcoEntrances com P N C 00139 Rev 10 20 17 SECTION 11 7 Single Full Automatic with Monitoring DN 1658...

Page 25: ...N O PWR PWR 1 RED BLUE BLACK 14 13 12 11 10 9 8 8 WHITE 14 13 12 11 10 9 8 7 6 5 4 3 2 1 6 4 5 COM N O PWR PWR Door Mounted Approach Side Sensor Door Mounted Swing Side Sensor COM N O PWR PWR COM N O...

Page 26: ...26 of 32 Opus Control Wiring and Programming Installation Manual www NabcoEntrances com P N C 00139 Rev 10 20 17 SECTION 11 9 Simultaneous Pair Full Automatic with Monitoring DN 1660...

Page 27: ...430 Clear A 70430 Dark Bronze RED BLACK 14 13 12 11 10 9 8 8 WHITE Off Hold Open On Off 14 13 12 11 10 9 8 8 14 BA break out input must be set to N C on the Opus Control is by default Panic Latch must...

Page 28: ...r connecting to a second Opus for Sim Pair Astragal Sequencing 14 13 12 11 10 9 8 10 14 Example of a switch being used to turn on off Power Close and Hold Closed Programmable input H terminal 10 would...

Page 29: ...irm that IN or EXT highlights when an activation signal isapplied If not check the wiring or the activation device X X At the main screen determine if BA is highlighted If a 4 wire on off hold openswi...

Page 30: ...he Opus will stop door movement Possible causes are X X Abnormal voltage at Motor Circuit X X Abnormal current draw from motor X X Check all connections between the Control and Motor X X Check Motor F...

Page 31: ...00888 CONTROLLER OPUS W CHASSIS BRAKE 9 M 01072 HARNESS POWER MAGNUM BOARD 10 V 00713 Used on A 01249 FUSE 2 AMP 5X20MM 250V FAST ACTING 11 A 01249 Used on GT710 8710 only HARNESS MOTOR OPUS 710 12 A...

Page 32: ...T 10 7 M 01680 HARNESS OPUS CONTROL SIM PAIR 8 A 01098 CONTROLLER W BRAKE BOTTOM LOAD OPUS 9 M 01735 PLATE BOTTOM LOAD OPUS 10 A 01143 CONTROLLER W O BRAKE BOTTOM LOAD OPUS 11 A 01003 Not used on GT71...