ICU 2400 Automatic Sliding Door Owners Manual 

www.NabcoEntrances.com

P/N C-00394 

Rev. 2-28-22

 

2 of 7

 

CHAPTER 1: WARNING LABELS

Please refer to this section in the event a warning label within this manual needs further explanation.

Indicates a hazardous situation which has 

some

 probability of 

severe injury

. It should not be 

considered for property damage unless personal injury risk is present.
Indicates a hazardous situation which may result in a 

minor injury

. Caution should not be used 

when there is a possibility of serious injury. Caution should not be considered for property damage 

accidents unless a personal injury risk is present.

Notice:  Indicates a statement of company policy as the message relates to the personal safety or protection 

of property. Notice should not be used when there is a hazardous situation or personal risk.

Attention: A situation where material could be damaged or the function repaired.

Note: Indicates important information that provides further instruction.

CHAPTER 2: GENERAL SAFETY RECOMMENDATIONS

An improperly adjusted door can cause injury and/or equipment damage.
Safety devices must be installed correctly and operational.
Do Not operate any Slide Door Unit without fully understanding how a Slide Door functions. If you 

do not fully understand, ask a qualified technician. Failure to do so may result in bodily injury, or 

property damage and will nullify all warranties.

Notice:  This manual must be given to and retained by the purchasing facility or end user.
Notice:  Inspect door operation daily using the Daily Safety Checklist (within this manual and on door).
Notice:  Have door inspected at least annually by an AAADM certified inspector.

CHAPTER 3: SCOPE

SECTION 3.1: To the Customer

The purpose of this manual is to familiarize the Owner with proper operation of the door. It is essential that the Owner 

recognizes the importance of maintaining a door system in compliance with industry standards for safety.   
It is the responsibility of the Owner/Caretaker to inspect operation of the door on a daily basis. Daily inspection must be done 

to ensure safe door operation for use by pedestrians, including (but not limited to) invitees, customers, or employees. This 

manual covers ICU 2400 Automatic Slide Doors.

SECTION 3.2: Objective

This manual provides operation and maintenance requirements, and instructions for a daily safety checklist.

Should the door fail to operate as prescribed in the Daily Safety Check, or at any other time for any 

other reason, DO NOT attempt to repair or adjust the door. Call an AAADM Certified technician. 

These technicians are trained to service automatic door systems in accordance with ANSI/BHMA 

A156.38 (Low Energy Power Operated Sliding and Folding Doors). 

CHAPTER 4: GETTING STARTED

ICU 2400 Automatic Slide Doors are available in a single slide configuration only. As a rule, the ICU 2400 Automatic is furnished 

as a complete package. This package typically includes: an Operator, Controller, Header, Track, Carrier Wheels,  

(1) Slide Door, (1) Sidelite, (2) Jamb Tubes, (1) Lock and an Activation/Safety System. Automatic Slide Doors:

 

X

Must include Sensors and Signage for the safety and convenience of the user.

 

X

Have a Safety Zone to cover the area the door travels.

WARNING

CAUTION

WARNING
WARNING
WARNING

WARNING

Summary of Contents for ICU 2400

Page 1: ...Entrances trained technician Failure to follow these practices may result in serious consequences NEVER leave a Door operating without all Safety detection systems operational Table of Contents CHAPTE...

Page 2: ...ly using the Daily Safety Checklist within this manual and on door Notice Have door inspected at least annually by an AAADM certified inspector Chapter 3 SCOPE SECTION 3 1 To the Customer The purpose...

Page 3: ...ld service This is NABCO ENTRANCES Inc s sole warranty This warranty does not cover loss or damages resulting from causes beyond the manufacturer s control misuse neglect accidents windstorms or other...

Page 4: ...ICU 2400 Automatic Slide Door System utilizes a Presence Sensor that activates the Slide Door with Infrared technology Infrared Technology is used to scan backwards to detect pedestrians in the thres...

Page 5: ...ting from floor such as marble or aluminum floors X Strong direct artificial light X Artificial light reflecting from floor such as marble or aluminum floors X Lighting fixtures placed too close to th...

Page 6: ...edestrian traffic is still restricted from Sensor activating zones The purpose of a Daily Safety Check is to ensure pedestrian safety and Owner protection 1 Ensure the Power Breaker is switched ON a D...

Page 7: ...or The signs shall be mounted 50 12 1270 mm 305 mm from the floor to the center line of the sign Description Caution Stand Clear Affixed on an adjacent Sidelite or Wall 36 to 60 inches from the floor...

Reviews: