4 of 26
GT 710-8710 OPUS Low Energy Swing Doors Quick Set-Up and Parts Guide
www.NabcoEntrances.com
P/N C-00178
Rev 12-20-17
CHAPTER 3: SCOPE
SECTION 3 .1: To the Installer
The purpose of this manual is to familiarize the installer and purchaser with the proper installation and operation of this system.
It is essential that this equipment be properly installed and operational before the door is used by the public. It is the installer’s
responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. In the United States,
ANSI Standard 156.19; ANSI Standard 117.1 and the Low Energy Operator section of ADA Standard covers the GT 710/8710 Swing Door
Low Energy System. Other local standards or codes may apply. Use them in addition to the ANSI standard. Low Energy Swing door Units
are listed with the Underwriters Laboratory and is identified as such on the label.
The owner should determine the door is operating properly and should immediately call for service if there is any malfunction. All
installation changes and adjustments must be made by qualified, NABCO trained technicians.
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 between
8 am – 4:30 pm Central time for additional assistance.
• Turn OFF all power to the Automatic Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
• NEVER leave a Door operating without all Safety detection systems operational.
SECTION 3 .2: Objective
The (8) 710 Swing Door system is designed to be installed within a Rough Opening of a Building. The door function is controlled by the
Opus Control. This control offers many features to accommodate most installation options. This manual offers step by step instructions.
A pedestrian Door that does not have Its glass sections installed at the Factory
shall specify that the glazing material employed is to comply with the requirement in UL 325
par.29.5.1:
“The glazing material in both fixed and sliding panels of all sliding doors and in all
unframed swinging doors shall comply with the requirements in the Performance
Specifications and Methods of Test for Safety Glazing Material Used in Buildings,
ANSI Z97 .1 . Glazing material for other pedestrian doors shall also comply with ANSI
Z97 .1, except that single strength or heavier glass may be used for those portions
of doors involving a glazed area of less than 1ft
2
(0 .9 m
2
) and having no dimension
greater than 18 in (457 mm)”
CHAPTER 4: INSTALL THE HEADER
1. Open the Inswing door 90 degrees.
a. Outswing doors do not need to be measured.
2. Measure between the wall and the outside face of the Swing Door. There must be a 2 inch minimum gap.
a. If there is less than a 2 inch gap, please call Customer Service at (877) 622-2694.
DN 1376
Building Wall
Space between Building Wall
and Face of Door must be at
least 2inches (or more)
Figure 1
Inswing Door Gap
WARNING
CAUTION