8 of 26
GT1400 Standard Single/Hurricane Single Folding Door Installation Manual
www.NabcoEntrances.com
P/N C-00177
Rev 6-14-21
4. Insert a Pin or 1/8 inch Allen Wrench into both Access Holes.
Do not allow the Pin or 1/8 inch Allen Wrench to drop out of the Access Hole at any time
during installation. The Guide Channel will spring back to its original location and can result in
personal injury or damage.
Figure 7
Insert Pin or 1/8 inch Allen Wrench
Operator
Insert Pin or Allen Wrench
Lovejoy Access
Coupling Hole
Access Hole
DN 0991
Opus Control Assembly
14
13
12
11
10
9
8
7
6
5
4
3
2
1
14
13
12
11
10
9
8
7
6
5
4
3
2
1
5. With the Guide Channel locked into the 90 degree open position, secure Header to the rough opening:
X
Standard Fold Door
•
Use 1/4 inch diameter anchors with a maximum 48 inches on center. First anchor maximum is 36 inches from each
end of the Header. Secure with appropriate Fasteners.
X
Hurricane Fold Door
•
Screw in anchors to secure the Frame (per manufacturer’s certification document(s).
CHAPTER 6: SHUT OFF CIRCUIT BREAKER
Shut the installation site, branch Circuit Breaker OFF. Failure to do so may result in serious
personal or fatal injury. When uncertain whether power supply is disconnected, always verify
using a voltmeter.
All high voltage electrical connections must be made by licensed electricians according to
National and Local electrical codes/regulations.
Permanent wiring shall be employed as required by local codes.
Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header. 120 VAC
Power wires must be routed (separate from other wiring) located near the top of inside Header.
Ensure that the Grounding of the Electric Power Supply is installed/connected in a proper way
(especially the PE Cable from the Building Side).
Attention: Insert all Incoming 120 VAC Power wires into the pre drilled Electric Service Access Hole located at the
left or right side of Header End Cap .
Attention: Electrical circuit to Nabco operator must not be not shared with other equipment such as lighting, cash
registers, or any device that might cause electrical interference on the circuit .
Attention: Any non-factory low voltage wiring added inside the Header must be Type CL2 wire or the equivalent
in accordance with Article 725 of the NEC .
Note: It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit.