8 of 32
Swing and Fold Door Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 8-11-21
SECTION 4.1 Level One: Specification Screens
Type:
GT710 Swing
Status:
Slow Closing
Error:
-----
Ac va on: IN EXT
Posi on:
> > > > > > > >
Other:
BA 6B SLS
Keep Pushing Switch
=> Se ng Mode
DN 1241
UNIT SPECS
ANSI specs (reference)
Opening Time to 80 deg
Closing Time to LCHK
LCHK to FullClosed
8
BA
1 12VDC
9
SQ
2 GND
10 Mul
3 61
11 M0
4 62
12 M1
5 6B
13 Out3
6 SWL
14 GND
7 Out2
Terminal
Error Screen
Mfg: 11/2016 Rev.B:21
Rotate
Dial
Rotate
Dial
Rotate
Dial
ANSI SPECS
ERROR SPECS
TERMINAL SPECS
Fully Closed
Figure 3
Level One Screens
Level One screens are used to inform the User all specifications that have already been programmed into the Opus Control. If a
specification needs to be changed, the User must reprogram the Opus Control within the Level Three screen, or Level Four screen.
When Power is turned ON for the first time, the Door does not move. Instead, an LCD screen will illuminate to display a Level One:
Unit Specification screen (Default screen). There are (4) Level One screens:
X
Unit Specifications:
•
Displays the type of door and current status of the unit . The type of door (swing, slide or folding) can be changed
within the Base Settings Category (Level 3 and Level 4) . Please refer to Subsection
The screen above
shows the Opus control installed on a GT710 .
X
Error Specifications:
•
This screen will only display an Error Code in the event there is an Error . Otherwise this screen stays blank .
DN 1249
Type:
GT710 Swing
Status:
Slow Closing
Error:
-----
Ac va on: IN EXT
Posi on:
> > > > > > >
Other:
BA 6B SLS
Keep Pushing Switch
=> Se ng Mode
UNIT SPECS
Recycle Warning!
Rotate
Dial
ERROR SPECS
Short
Push
FLASHING
SCREEN
Long
Push
Recycle Warning!
Clear Yes No
ERROR SPECS
Rotate
Dial
Recycle Warning!
Clear No
ERROR SPECS
Yes
Short
Push
Figure 4
Example: Clear an Error Code for Recycle Warning
X
ANSI Specifications:
•
Displays the actual time of opening and closing of the door to help determine ANSI compliance .(Applies to swing
doors only) .
X
Terminal Specifications:
•
Displays the current status of all of the Input/Output lines of the terminal strip .
SECTION 4.2 Level Two: Access Screen
Note: The “Activate Passcode” option is only displayed in the event “0045” had not already been entered.
DN 1713
Passcode
Stroke Learning
Yes No
LEVEL 2
Rotate
Dial
Passcode
Stroke Learning
Yes No
Passcode
Go to Se ng Menu
Stroke Learning
Passcode
Go to Se ng Menu
Stroke Learning
Go to Se ng menu
Reset to Default Set
Yes
No
Passcode
Stroke Learning
Yes No
Ac vate Passcode
Rotate
Dial
Rotate
Dial
Rotate
Dial
Figure 5
Level Two Screen
Attention: To prevent tampering, a Universal Passcode (0045) has been programmed into all Opus Controls. This
Passcode cannot be changed, but can be turned OFF and ON.