Turn the Rotary Dial (2) clicks to advance through each menu item:
•
Clockwise: To scroll forward through screens and programming options .
•
Counterclockwise: To scroll backward through screens and programming options .
SECTION 3.8: IO Terminal strips
I/O Terminal Strips (1 thru 14)
1
12VDC +12VDC
8
BA
Breakout
2
GND
Common for 12V and signals
9
SQ
Sequential activation (signal to open, signal to close)
3
61
Interior Activation
10
H
Reduced Open (Programmable Input)
4
62
Exterior Activation/Programmable Input
11
M0 Mode 0 One way when
connected to Common
Hold Open when
both M0 and M1
connected to
Common
5
6B
Continuous Safety
6
SWL
Default setting: Safety with Lockout
12
M1 Mode 1 Night when connected
to Common
Rev 27 & Later: Input is programmable
7
Out1
Sensor Monitoring (Programmable Output)
13
Out 2 Aux. Output 2, Programmable output, closes to GND
Closes to Common
14
GND Common for all above signals
SECTION 3.9: Relay Output Terminal Strip
Relay Output 3
COM
Common
N.C.
Normally Closed Contact
N.O.
Normally Open contact for Sensor Monitoring
SECTION 3.10: CAN Bus Communication
Used to connect Sim Pair, Astragal, Sequencing and the NET-HT Cable when programming.
CHAPTER 4: LCD CATEGORY SCREENS
Passcode
Go to Se ng Menu
Stroke Learning
Yes No
UNIT SPECS
ERROR
ANSI
TERMINAL
Long
Push
LEVEL 1
LEVEL 2
Rotate Dial to navigate screen. Short Push Dial to select
Se ng Category
LEVEL 3
Parameter
Op ons
Base Se ng
Operator Type/Low or Full Energy/Handing/Encoder
Movement Se ng
(Rotate Rotary Dial)
Open Speed/Back Check Speed/Back Check Range/Close Speed/Latch Check Speed/
Latch Check Range/Open Timer/Reac on Power/Open Recycle Sens/Close Recycle Sens/
A er Open Recycle
Op onal Se ng
Hold Close Force/Power Close Range/Manual Open Func on/Manual Open Sens/Manual
Open Timer/BCHK Lockout Angle/LCHK Lockout Angle/Stop Force adjustment/SimPair Se ng
Output Se ng
Output1 Se ng/Output2 Se ng/RelayOutput3 Se ng/Open Delay Timer/
Sequence Delay Timer/Lock Condi on
Input Se ng
Input 62 Se ng/Input 62 Open Timer/Input H Se ng/Input H Open Timer/Input 61 Circuit/
Input 62 Circuit/Input 6B Circuit/Input SWL Circuit/Input BA Circuit/6B Stop Closing/A er 6B
Open?/61 Monitoring/62 Monitoring/6B Monitoring/SWL Monitoring
History Data
Opera on Cnt/Open Recycle Cnt/Close Recycle Cnt/Latest Recycle Posi on
DN 1334
LEVEL 4
Push and Hold Rotary Dial (2 Sec.)
Rotate
Dial
Rotate
Dial
Rotate
Dial
Short
Push
Figure 2
LCD Screen Transition