11
3 - Machine Maintenance
In order to keep the Breeze™ running smoothly and
reduce the risk of damage to the machine and subsequent
downtime, Mytee recommends following the maintenance
schedule below:
Maintenance Item
Daily
Weekly
Clean and inspect tanks.
X
Clean and inspect hoses.
X
Check and clean internal filters.
X
Check power supply cables.
X
Clean machine with all-purpose
cleaner and cloth.
X
Flush solution system with Mytee
System Maintainer.
X
Run clean water through the
chemical injection system
(BZ-105LX-AUTO only).
X
Inspect vacuum hoses for holes and
loose cuffs.
X
Inspect machine for water leaks and
loose hardware.
X
3.1 - Opening the Unit for Maintenance
To open the Breeze™, loosen the latches on the front of the
unit by turning them one quarter turn counter-clockwise.
Flip the latches down and then lift up on the handle and the
machine will open up.
♦
3.2 - System Maintainer
Weekly flushing of the solution system with Mytee®
System Maintainer helps keep lines clean and prevents
chemical build-up, improving pump life, performance and
pressure.
How to use System Maintainer:
1. Mix 1-quart 3601 System Maintainer with 1-quart of
warm water.
2. After thoroughly mixing, pour this solution into the
solution tank.
3. Turn the pump on FIRST, and run solution through your
cleaning tool. NOTE: The jet should be removed from the
cleaning tool in order to prevent clogging due to loosening
of deposits in line.
4. Next, turn on the heater (if equipped). If the heater is
turned on first, it will result in a vapor lock, which will affect
the machine’s operation.
5. Next, with both the pump and heater on, begin running
the solution through the machine. This allows the solution
to break down any build up in the lines.
6. After running all of the solution through the machine, fill
the tank with clean, warm water. Run the water through the
machine to clear the solution completely out of the tank &
lines.
♦