![mySmart MWS6-PRM-2CH Product Manual Download Page 1](http://html1.mh-extra.com/html/mysmart/mws6-prm-2ch/mws6-prm-2ch_product-manual_1863203001.webp)
Ceiling Microwave presence/absence detecrto2 channel
Overview
The MWS6 -PRM -2CH Microwave presence detector
provides automatic control of lighting loadswith optional
manual control. It detectsmovement using a highly
sensitive microwave detector. This worksby emitting low
power microwave signalsand measuring the re ections as
the signalsbounce o moving objects.
The detector provides two independently controlled output
channels that can be used for avariety of applications.
Occupancy of two independent lighting circuitsusing
a single detector, e.g. for essential and non
-essential
supplies.
Occupancy and lux control of one lighting circuit and
just occupancy control of a second circuit, e.g. where
a row of luminariesby a window islux controlled
whilst inner rows are switched on occupancy only .
Occupancy and lux control of alighting circuit and
just occupancy control of aventilation circuit .
Occupancy on both lighting circuits, with separate lux
control on each circuit.
All functionality isfully programmable using an IRhandset.
MWS6 -PRM -2CH
Ceiling Microwave presence/
absence detector 2 channel
MWS6 -PRM -2CH -NC
Ceiling Microwave presence/
absence detector 2 channel
normally closed
Features
Front features
Mounting Bezel
Back features
Retaining Spring
Sensor Lens
which covers...
Microwave Sensor
IRReceiver
Light LevelSensor
Status LEDs
Channel 2
Connector
MicrowaveSensor
Detects movement within the unit’s detection range,
allowing load control in response to changes in occupancy.
IRReceiver
Receives control and programming commands from an
IR(infrared) handset.
LightLevelSensor
Measures the overall light level in the detection area
Status LEDs
The LED ashes
R
ed to indicate the following:
Walk Test LEDactive
when movement is detected
Valid setting received
Channel 1 Connector
Live input and output for Channel 1. Switch input
connection that can be used to manually override the lights
on or o .
Channel 2 Connector
Live input and output for Channel 2. Common Neutral
connection.
Channel 1
Connector
Retaining Spring
MWS6-PRM-2CH, MWS6-
PRM-2CH-NC
Product Guide