Manual No. 775064
D-1
Appendix D
Enclosure Management
Introduction
Mylex’s AcceleRAID controllers support the industry standard enclosure
management protocol
SCSI Accessed Fault-Tolerant Enclosures
(SAF-TE).
This feature allows the host to monitor drive enclosures and detect certain
faults or operating environment conditions. The host can make a decision to
shut down the system or issue a warning based on the type of fault detected.
SAF-TE
The SAF-TE protocol follows a specification jointly worked out by Conner
Corporation and Intel Corporation. Enclosures that are compliant with this
protocol are known as SCSI Accessed Fault-Tolerant Enclosures (SAF-TE).
The protocol is compatible with standard SCSI buses and cabling.
The SAF-TE interface standard’s objective is to provide a non-proprietary
means of allowing third-party disks and controllers to be automatically
integrated with peripheral enclosures that support:
• Status Signals (LEDs, audible alarms, LCDs, etc.)
• Hot swapping of drives
• Monitoring of fans, power supplies, and enclosure temperature
SCSI is the underlying transport mechanism for communicating enclosure
information. All standard SCSI host adapters will work. There is no need to
consider reserved signals or special cabling.
The SAF-TE interface can be implemented as a SCSI target that uses a SCSI
port and an 8-bit microcontroller.
All communication is initiated by the host. The SAF-TE processor acts only
in target mode. The SAF-TE processor is periodically polled by the host
approximately every 2 to 10 seconds.
Summary of Contents for AcceleRAID 170
Page 1: ......
Page 2: ......
Page 10: ...viii AcceleRAID 170 Installation Guide...
Page 16: ...User supplied Items 1 6 AcceleRAID 170 Installation Guide...
Page 38: ...In Case of Problems 3 6 AcceleRAID 170 Installation Guide...
Page 44: ...System Reboot or Power Down B 4 AcceleRAID 170 Installation Guide...
Page 55: ...Regulatory Information Manual No 775064 E 5 Underwriters Laboratories Statement and Warning...
Page 56: ...Underwriters Laboratories Statement and Warning E 6 AcceleRAID 170 Installation Guide...
Page 82: ......
Page 85: ......
Page 86: ......