General Safety Information / Electrical

2

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential for
personal injury.

warns about hazards that 

will

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.

The label 

NOTICE

indicates special instructions which are

important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Hazardous pressure. Under certain condi-

tions, submersible pumps can develop extremely high
pressure. Install a pressure relief valve capable of passing
entire pump flow at 75 PSI.

Do not allow pump, piping, or any other system

component containing water to freeze. Freezing may
damage system, leading to injury or flooding. Allowing
pump or system components to freeze will void warranty.

Hazardous voltage. Can shock, burn or

cause death. To avoid dangerous or fatal electric shock
hazard, use pump only in an effluent system. DO NOT
install pump in an open body of water ( a lake, swimming
pool, etc.).

Install, ground and wire pump according to local

and Canadian Electrical Code or National Electrical Code
requirements that apply.

Disconnect electrical power supply before installing

or servicing pump.

Make sure pump nameplate voltage and frequency

match line voltage and frequency of power supply.

1. Install pump according to all plumbing, pump and

well code requirements.

2. Install an all leg disconnect switch in the power supply

near the pump.

3. Two-wire motors are equipped with automatic thermal

overload protection which will open the circuit and
stop the motor when a thermal overload (excessive
heating) exists. When motor cools, overload will rest
and motor will restart automatically. 

This can cause

the pump to start unexpectedly and without warning.

GENERAL

Inspect pump for delivery damage. Report any damage to
shipping carrier or to Myers immediately.
Have any installation, repair, or service work done by your 
Myers dealer.
Never run pump dry.
During system operation, pump must  be submerged at all
times.
Pipe joint compound can cause cracking in plastics. Use
only teflon tape when sealing joints in plastic pipe or con-
necting pipe to thermoplastic pumps.
Warranty is void in the following conditions:
•  Water is highly corrosive.
•  If entrained gas or air present in water being pumped

reduce the flow and cause cavitation (which can dam-
age the pump).

•  Pump has been operated with discharge valve closed

(severe internal damage will result).

ELECTRICAL

Wiring/Grounding

Hazardous voltage. Can shock, burn, or

cause death. Permanently ground pump, motor and con-
trol box before connecting power supply to motor.

Ground pump and motor in accordance with all codes
and ordinances that apply. All wiring must meet National
Electrical Code and Canadian Electrical Code (whichever
applies). Use copper ground wire at least as large as wires
carrying current to pump.
Pump is supplied with copper ground wire. Use only cop-
per wire for connections to pump.

TABLE 1: RECOMMENDED FUSING DATA

60 Hz/1 Phase 2-Wire Cable

Max.

Locked

Fuse Size

Volts/Hertz/

Load

Rotor

Standard/

Model

HP

Phase

Amps

Amps

Dual Element

10MD05221

1/2

115/60/1

11.0

30.0

15

20MD05221

1/2

115/60/1

9.5

30.0

15

30MD05221

1/2

115/60/1

9.5

30.0

15

Summary of Contents for 10MD05221

Page 1: ...ev 4 18 05 1101 Myers Parkway Ashland OH 44805 Phone 1 419 289 1144 Fax 1 419 289 6658 Web Site http www myerspump com 10MD05221 20MD05221 30MD05221 Installation Operation Parts For further operating installation or maintenance assistance Call 1 419 289 1144 ...

Page 2: ...ng pump and well code requirements 2 Install an all leg disconnect switch in the power supply near the pump 3 Two wire motors are equipped with automatic thermal overload protection which will open the circuit and stop the motor when a thermal overload excessive heating exists When motor cools overload will rest and motor will restart automatically This can cause the pump to start unexpectedly and...

Page 3: ...nection to box All control compo nents must be UL listed and suitable for end use application 5 Do not pump flammable liquids strong caustics or strong acids with this pump Do not use with salt water or brine 6 To prevent dropping pump lower it by the drop pipe not by the cables The electrical cables will not hold the pump weight 7 Discharge outlet is 1 1 4 NPT threaded NOTICE If installing extern...

Page 4: ...ed replace it Clean tank of all sand lime or solids before reinstalling pump Power supply Consult licensed electrician or Have a qualified serviceman or electrician make wires or pump qualified serviceman necessary cable repairs leads grounded shorted or open Fuses blow or overload protector trips when motor is running Low or high Check that line voltage is within If voltage variation is more than...

Page 5: ...his Warranty must be returned to MYERS in Ashland Ohio or such other place as MYERS may designate freight prepaid PRODUCT IMPROVEMENTS MYERS reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for units sold and or shipped prior to such a change or improvement WARRANTY EXCLUSIONS MYERS SPECIFICALLY DISCLAIMS T...

Page 6: ...6 ...

Page 7: ...1 Myers Parkway Ashland OH 44805 Téléphone 1 419 289 1144 Télécopieur 1 419 289 6658 Site Web http www myerspump com 10MD05221 20MD05221 30MD05221 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 419 289 6658 ...

Page 8: ...onformément aux pompes et aux puits 2 Près de la pompe installer un disjoncteur sur le circuit d ali mentation 3 Les moteurs à deux fils sont équipés d un protecteur ther mique qui détecte les surcharges et les surchauffes Ce pro tecteur ouvre le circuit dès que les surchauffes et surcharges deviennent excessives et le referme dès que le moteur refroid it La pompe peut alors redémarrer inopinément...

Page 9: ... de courant côté boîte de commande Tous les composants de commande doivent être classés UL et répondre aux besoins de l utilisa tion 5 Avec cette pompe ne pas pomper de liquides inflammables ni de caustiques ou d acides forts Ne pas pomper de saumure ni d eau salée 6 Pour éviter de laisser tomber la pompe l abaisser en se ser vant du tuyau de descente et non pas des câbles Les câbles électriques n...

Page 10: ...s matières solides pouvant se trouver dans le réservoir Fils électriques ou Consulter un électricien ou un Faire procéder aux réparations nécessaires des câbles de la pompe à la technicien qualifié par un électricien ou un technicien qualifié terre en court circuit ou cassés Les fusibles ou le protecteur thermique saute pendant que le moteur fonctionne Tension basse Pendant que le moteur fonctionn...

Page 11: ...t par MYERS AMÉLIORATIONS APPORTÉES AUX PRODUITS MYERS se réserve le droit d apporter des modifications ou d améliorer ses produits ou une partie de ceux ci sans être dans l obligation d apporter de telles améliorations ou modifications aux produits vendus ou expédiés avant que de telles modifications ou améliorations aient été apportées EXCLUSIONS À LA GARNTTIE MYERS DÉCLINE EXPRESSÉMENT LES GARA...

Page 12: ...6 ...

Page 13: ...5 1101 Myers Parkway Ashland OH 44805 Teléfono 1 419 289 1144 Fax 1 419 289 6658 Dirección web http www myerspump com 10MD05221 20MD05221 30MD05221 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 419 289 1144 ...

Page 14: ...nterruptor de desconexión en la fuente de sumin istro de potencia cercano a la bomba 3 Los motores bifilares vienen equipados con un dispositivo de protección automática contra sobrecarga térmica que abre el circuito y detiene el motor cuando ocurre una sobrecarga tér mica demasiado calor Cuando el motor se enfría la sobre carga descansa y el motor se vuelve a encender automática mente Esto puede ...

Page 15: ...rol para la conexión del cordón de suministro de potencia a la caja Todos los componentes del control deben estar aprobados por UL y deben ser adecuados para el uso final 5 No bombee líquidos inflamables cáusticos fuertes o ácidos fuertes con esta bomba No la use con agua salada o salmuera 6 Para evitar la caída de la bomba bájela por medio de la tubería descendente no por medio de los cables Los ...

Page 16: ...e arena cal o partículas sólidas antes de volver a instalar la bomba Los cables de suministro Consulte con un electricista certificado Hacer que un técnico de servicio o electricista de potencia o los o con un técnico de servicio competente certificado realice las reparaciones necesarias en los conductores de la cables bomba están conectados a tierra en cortocircuito o abiertos Los fusibles se que...

Page 17: ... MYERS en Ashland Ohio o a cualquier otro lugar que MYERS pueda designar con flete prepago MEJORAS DEL PRODUCTO MYERS se reserva el derecho de cambiar o de mejorar sus productos o cualquier parte de los mismos sin estar obligada a proporcionar tal cambio o mejora para las unidades vendidas y o enviadas antes de la introducción de tal cambio o mejora EXCLUSIONES DE LA GARANTÍA MYERS NIEGA TODA RESP...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: