7.8.17.
Errors and alarms
During the preparation and execution of any of the programmes available in the oven,
errors and alarms may occur. If an error occurs in the system during use, it will be displayed
in the error list.
The table below shows the different errors and alarms, as well as possible solutions to them.
Error
Internal definition
Clarification
0
NO ERROR
No error.
1
GENERAL PURPOSE INPUT
ERROR
General error input. Not used.
2
OVERTEMPERATURE ERROR
General temperature input. Not used.
3
OVERTEMPERATURE PCB
ERROR
Overtemperature PCB. Check that the cooling
fans of the electronics are working properly, that
there is enough space between the back and the
wall, and that the ambient temperature is not
excessive.
4.1
PCB RELAYS ERROR
Communication between boards is not
responding. Check the cable connecting the
power board and the control board.
4.3
INVERTER ERROR
Communication between relay board and motor
inverter. Check the cable connecting the two
components. Check if the inverter communication
LED is flashing.
4.7
HOOD ERROR
Communication between boards is not
responding. Check wiring.
4.8
PROOFER ERROR
Communication between boards or sensors not
responding. Check wiring.
4.9
STATIC OVEN ERROR
Communication between boards or sensors not
responding. Check wiring.
5
EEPROM ERROR
Processor and EEPROM communication do not
work. Check control board.
6
ENGINE ERROR
Motor error. Check motor wiring. Motor
overtemperature. Motor stuck.
7
ALARM WATER
No water detected. Make sure that the water
mains are correctly connected.
8
ERROR WASHING
No detergent/brightener detected. Not used.
9
ERROR PROBE1 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check external
probe and connector.
10
ERROR PROBE1 TEMP SENSOR
SHORTED
External probe short-circuited. Check external
probe and connector.
11
ERROR PROBE2 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check external
probe and connector.