210208_A
mychefcooking.com
12
PRODUCT MANUAL EVOLINE - DT.MP.EV.2103.2
5.2.
Water connection (appliances with humidity)
5.2.1.
Water input
Cold water (max. 40°C) ¾ inch 100 to 400 kPa dynamic flow pressure.
Drinking quality water with the following characteristics:
-
Hardness between 3º and 6º FH
-
PH between 6.5 and 8.5
-
Chlorides lower than 30 ppm
The use of a water softener is recommended (BRITA Purity Steam 450
recommended).
5.2.2.
Drain (appliances with humidity)
The equipment must be connected to a drainage system with a nominal diameter of 40mm
(DN40) through a heat-resistant pipe and siphon type.
Note that the tube must have a constant slope of at least 5°.
The drain must be a maximum of 1 meter long, have a diameter greater than
the drain connection and be free of bottlenecks.