background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

High Precision Balances 

iBalance 601 

iBalance M01 

 

 

(LED Display) 

 

 

 

 

Operation Manual

 

 
 
 
 
 

                                                                      KD-TBED-en,V1.2-2005 
 
 

 

Summary of Contents for iBalance 601

Page 1: ...High Precision Balances iBalance 601 iBalance M01 LED Display Operation Manual KD TBED en V1 2 2005 ...

Page 2: ...and zero display Press the key until the display shows 0 5d 1 0d 1 5d 2 0d 3 0d to power on press the key to select the range of zero tracking press to confirm Then it will display ZEr S or ZEr L press to select the zero display range ZEr S mean 0d ZEr L mean 3 0 d press to confirm then choose the Communication method by pressing the Key to rotate revolve Con send in succession stable send steadil...

Page 3: ... your warranty 2 Do not drop or shock the scale and do not drop any item onto the scale or tray It may cause permanent damage Only operate the scale gently and place items on the tray gently Overloading the balance will damage the weighing sensor 3 Extreme temperature humidity fluctuations shocks and vibrations should be avoided at all times 4 If the scale will not be used for a long time please r...

Page 4: ...fication model iBalance601 iBalanceM01 Maximum capacity 600g 1000g Display scale interval d 0 01g 0 01g Pan size Ø116mm Ø116mm Power source Rechargeable battery 6v 1 3Ah or 8 5v 0 2A AC DC adaptor V Explanation of display symbols 2 2D HEX negative sign 20 HEX blank 2E HEX decimal point UNIT 4 byte g 20 HEX 20 HEX 20 HEX 67 HEX kg 20 HEX 20 HEX 6B HEX 67 HEX ct 20 HEX 20 HEX 63 HEX 74 HEX ozt 20 HE...

Page 5: ... 8 bits 3 Parity bit none 4 Stop bit 1 bit 5 Code ASCII DATA FORMAT HEAD1 HEAD2 DATA UNIT CR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 HEAD1 2BYTES HEAD2 2BYTES OL overload NT net weight mode ST stable US unstable DATA 8BYTE 6 Explanation Of Display Symbols Scale is in ZERO mode Scale is in TARE mode Scale needs recharging once this battery appear The display reading is in STABLE conditio...

Page 6: ...lution will be shown VIII Operations Weight units Press key to choose the preset weight units g ct ozt Tare function 4 Put a container on the pan and press when the display reading is stable The tare weight will be stored into memory and display will be brought to zero indication in the display will appear The weight will be displayed as net weight To cancel the tare mode press when no load on the...