INSTALLATION: 

READ THIS BEFORE OPERATING UNIT 

MAINTENANCE: 

Mount on clean,  flat surface.  Bolt down with 4-1/2"  bolts,  grade 5 or 

better,  For ease of service,  we do not recommend welding frame to 

surface. 

Connect a battery cable from the positive battery post or 12V DC power 

supply to the positive post on the winch control box (p/n 281750) using the 

boot provided.  Connect a  battery cable from the negative battery post to 

the grounding post on the winch frame.  The negative cable may not be 

required when the winch and the battery or power supply are connected to 

a common ground.  Use #4 battery cable or larger for cable runs up to 10'. 

Use #2 battery cable or 

for cable runs from 11-25'.  For vehicle 

mounted applications,  a 

mounted disconnect switch may be used to 

disconnect power to the winch when it is not in use.  This will prevent 

accidental engagement of the winch motor during travel.  Contact My-te for 

more information. 

ROPE USAGE AND SAFETY: 

The capstan drum winch-hoist is designed to be used with rope of 1/2" to 

3/ 4" diameter to winch or hoist loads requiring up to 800 Lbs.  of single 

line pull.  Polyester or  Dacron rope makes a good rope choice due to its 

resistance to  heat generated by drum friction.  Do not use wire rope. 

Wrap the rope around the drum placing the load line closest to the gear 

box.  To hoist or retrieve the load,  the operator must pull the fall line (the 

unloaded end of the rope)  from the drum by hand as the drum rotates.  To 

tower the  load, carefully pay  the  fall line back  onto the drum allowing the 

wraps of rope to slip,  thus lowering the load.  An alternate method of 

lowering a load is to operate the winch-hoist in the lifting direction while 

paying rope back onto the drum. 

The proper number of wraps is determined by feel.  Take time to become 

familiar with the capstan's operation.  Feeding off and paying back of the 

fall line should require minimal effort.  Use at least 3 wraps of rope on the 

drum. Heavier loads may require 4 wraps. Do not place so many wraps on 

the drum as to allow the rope to ride over the end of the drum.  If the load 

requires excessive operator effort or more than 4 wraps of rope on the 

drum, a two part line and traveling sheave block must be used.  If this does 

not alleviate the problem, check the weight e>f the load and be sure rope 

travel and load path are unrestricted.  Do not overload the winch-hoist! 

OPERATION: 

Extreme caution should be exercised when operating any winching or 

hoisting equipment as loss of control over the load may result in property 

damage,  injury or death.  Operation of such equipment should only be 

performed by qualified personnel. 

The 30-12 and 30-12/FS are designed for intermittent operation.  My-te 

recommends a 25% duty cycle. For optimum motor and control life, do not 

exceed 15 minutes of run time per hour at full load. 

To prevent shock loading,  slowly remove slack from rope before full load is 

moved. 

Hand held or  foot operated pendant provides forward and reverse control 

through  winch-hoist control solenoids.  Pulling power is the same in either 

direction. 

If the unit is installed outside,  a cover may be provided to protect motor 

and controls from the inclement weather.  Do not allow the cover to 

interfere with the capstan drum. 

Frequent inspection of the winch including battery cables and pendant 

should be made to detect any damage that may affect proper operation of 

the unit. 

A periodic inspection should include a check of all hardware to ensure that 

fasteners have not worked loose.  This includes the locking collar on the 

218010 flangette bearing assembly, as well as the capstan drum set 

screws.  Check the gear box oil and bearing lubrication as described in the 

attached Lubrication Guide.  Check electrical connections for corrosion. 

TROUBLE SHOOTING AND REMEDIES: 

If the unit does not run,  check power supply.  Be sure correct voltage is 

being applied.  Verify that the winch-hoist is well grounded to the 12.V  DC 

power supply. 

Check all connections in the winch-hoist control box.  Check connections in 

the hand held or foot operated pendant. 

Check for damage to the battery cables and pendant cord. 

If a cab mounted cut-off switch or circuit breaker/fuse has been installed in 

the power supply to the winch-hoist,  check for proper wiring and operation 

of these components. 

If the control solenoid(s)  click(s)  but the winch-hoist  does not run, 

determine whether the problem is in the motor or the wi.nch-hoist control 

panel.  This may be done by checking for 12V DC voltage at the motor 

terminals on the outboard end of  the motor when the pendant switch is 

operated.  Operating the pendant in the opposite direction should reverse 

polarity of the voltage.  Proper voltage at the motor indicates that the 

problem is most likely in the motor. 

Motor brushes may be replaced.  Contact the factory,  your My-te dealer or 

a motor repair shop for assistance.  In order to remove the motor, the 

118081 pinion gear must first be removed. 

WARRANTY: 

All My-te winch-hoists are designed for material handling use only ..  My-te 

Products,  Inc.  warrants each My-te winch-hoist to be free of defects in 

material and workmanship for a period of one year This warranty does not 

cover abuse, neglect or use above or beyond rated capacity and duty cycle. 

Warranty coverage includes shipping charges·, one way,  by standard 

ground service. Warranty does not cover cost of installation or removal of 

winch-hoist from service or loss due to downtime or time out of service. 

My-te will not reimburse unauthorized warranty expense. The final 

responsibility for flt of winch-hoist with application rests with end user. The 

warranty is void if the winch-hoist is altered or parts substituted.  This 

warranty is limited to repair or replacement at manufacturers factory o·> a 

point designated by the manufacturer.  Inspection by the manufacturer will 

determine manufacturers liability. 

All  MY-TE WINCH-HOISTS ARE DESIGNED FOR  MATERIAL HANDLING USE ONLY. 

My-te Products, Inc. 

9880 East 30th St.,  Indianapolis, IN 46229 

317-897-9880

317-897-9811 (fax)

www.myte.com 

[email protected] (E-mail) 

Provided by: www.hoistsdirect.com