background image

MF 1100 A

USER

MANUAL 

+90 ( 212 ) 222 0946
+90 ( 212 ) 222 0947

[email protected]

Phone   : 
Fax       : 

Email     : 

www.mwf.com.tr

Website : 

Summary of Contents for MF-1100 A

Page 1: ...MF 1100 A USER MANUAL 90 212 222 0946 90 212 222 0947 info mwf com tr Phone Fax Email www mwf com tr Website...

Page 2: ...Contents User s Maual Page 1 Contents Overview Important Notes Main Unit Parts Assembly Setup Getting Started 1 2 3 5 7 8 9 12 Confirm Target 18 Metal and Water Finder...

Page 3: ...Rings watch belt Any attempt to tamper the device or unapproved maintenance would void the warranty For best power endurance and reliability use heavy duty and high quality batteries The user must pra...

Page 4: ...d by the soil electrostatic fields that absorbed from different sources like power stations radio and tv transmitting stations satellites lightning and so others electrostatic and power generators Thi...

Page 5: ...Electrostatic Fields of the Buried Target Operating Processor Microcontroller Processor Frequency 20 000 MHz Processing Type Digital Signal Processing DSP Operating Frequency 1 30 KHz Search Depth Pr...

Page 6: ...Main Unit MF 1100 A 1 4 5 6 3 2 Front View Page 5 Scanning Antennas plugs 1 Display 2 Power Switch 3 Navigation And selecting Button Move 4 Confirm And Enter Enter 5 Escape And Restart Button ESC 6...

Page 7: ...Main Unit MF 1100 A 8 9 10 7 Back View Page 6 Primary Battery Cover 7 Grip Socket 8 Secondary Battery Cover 9 Secondary Battery Power Switch 10...

Page 8: ...y And Navigate The Device Easily With The Rotaion Ability Grip Connect this unit to the device and plant it to the ground before heading towards target This unit sends and reinforces the waves in the...

Page 9: ...front gure 1 1 Connect the grip to the socket in the bottom of the device gure2 0 2 Connect the power supply which is 9v battery in the battery housing gure 3 Don t mix Different volts and types of ba...

Page 10: ...e Main Menu would appear Metal Tupe Search Distance Seatch Depth After the boot screen the language list would appear the user must specify the system language by navigating to the chosen language pre...

Page 11: ...en selecting by pressing ENTER then a list with the searchable metal types would appears on the screen which is Gold silver Bronze diamond and raw gold navigate to the desired metal pressing MOVE Then...

Page 12: ...The Search will start automatically As shown in the figure below Setup MF 1100 A Page 11 Select depth 4 10 m 5 15 m 6 20 m Searching in order to start the search the last setting must be configured w...

Page 13: ...e device towards the soil to be automatically configure the soil as shown in the figure below Until the configured options menu appears as shown in the figure below To reset the settings again or to c...

Page 14: ...he assembly and the setup connect it to one of the middle antennas plugs and plant it to the ground for a period of 2 1 minutes then disconnect it and reconnect the antenna and complete the search ope...

Page 15: ...e user must carry the device by grip horizontally slightly sloped towards ground as shown in the figure below Then stimulate the device s waves and output fields by moving the device right and left sl...

Page 16: ...ll the tracks intersect in a point then it is the target point Getting Started MF 1100 A Page 15 the user can know and estimate the target distance from the search location to do so escape to the main...

Page 17: ...ly until you reach the passing point you will notice that the device rotates around the normal track towards the point Rotate with device slowly and start walking towards the target slowly until you r...

Page 18: ...Direction User The user can know the approximate target depth by returning to main menu and select search settings all again and change the depth level from depth menu for example if the first select...

Page 19: ...oves towards the target then it is 100 legit and if the device moves towards the filter then it is a natural ore in the target point and not a burial therefore you can disregard the target Usage This...

Page 20: ...Valid Operation Confirm Target MF 1100 A Page 19 Soil Natural Ore Invalid Operation Soil Real Target...

Page 21: ...Metal and Water Finder...

Reviews: