background image

HDMI 4x4 Matrix Switch, 4K/60

 

 

 

 

 

 

 

Installation Guide

 

© Muxlab Inc. 2020

 

 

 

 

 

 

 

 

 

 

6

 

6. Remote Control 

 

① Power: Press the button to turn on/off the unit.

 

② Input Select for HDMI Output 1:

 

Press 1, 2, 3 or 4 to select the desired input source for HDMI Output 1.

 

③ Input Select for HDMI Output 2:

 

Press 1, 2, 3 or 4 to select the desired input source for HDMI Output 2.

 

④ Input Select for HDMI Output 3:

 

Press 1, 2, 3 or 4 to select the desired input source for HDMI Output 3.

 

④ Input Select for HDMI Output 4:

 

Press 1, 2, 3 or 4 to select the desired input source for HDMI Output 4.

 

 
 

7. Operate and Connect 

 

1.

 

Make sure all equipment is powered off. Insert and connect cables carefully with the power SWITCHED 
OFF. Connecting and disconnecting cables while the unit is powered can result in damage to equipment. 

2.

 

Connect upto 4 sources such as a Blu-Ray Player, a game console, an A/V Receiver, a Cable or Satellite 
Receiver, etc. to the HDMI inputs on the unit. Note that high-quality/premium 4K HDMI cables are 
recommended. 

3.

 

Connect the HDMI output ports to Ultra High-Definition displays such as an 4K TVs and projectors that 
support HDMI connectivity. Note that high-quality/premium 4K HDMI cables are recommended. 

4.

 

For power, plug in the unit power jack first, and then plug in the power supply to the wall. 

5.

 

Power on each device in the same sequence. At this point each display connected should display the 
assigned source (input 1 at default when powered on initially), scroll through each of the sources on each 
display to ensure everything is in proper working order. Use the included IR remote to test the switching 
function. If a display is having difficulty receiving the HDMI 

signal, access the display’s menu and adjust 

the resolution (lowest to highest until signal is displayed). Please note that a 24 Hz vertical refresh rate 
may work better than 60 Hz or higher.   

 

 

Summary of Contents for 100508

Page 1: ... Muxlab Inc 2020 94 000934 A SE 000934 A HDMI 4x4 Matrix Switch 4K 60 Operation Manual 100508 ...

Page 2: ...ar water Keep the product away from liquids Spillage into the housing may result in fire electrical shock or equipment damage If an object or liquid falls or spills on to the housing unplug the module immediately Do not use liquid or aerosol cleaners to clean this unit Always unplug the power to the device before cleaning Using supplies or parts not meeting the products specifications may cause da...

Page 3: ...cted output port to the specify input port 13 3 2 2 Map all the output ports to an input port 13 3 2 3 Read all the output mapping information 14 3 3 Network configuration 0x05 14 3 3 1 Network setting Sub command 14 3 3 2 Read Matrix switch current IP information 15 3 3 3 Configure DHCP static IP mode 16 1 Introduction The HDMI 4x4 Matrix 4K 60 connects Four 4 HDMI sources to Four 4 displays This...

Page 4: ...ultiple displays at the same time Allows any HDMI display to view any HDMI source at any time Supports RS 232 control TCP IP Control IR Remote Control and On Panel Control HDMI connectors with Locking nuts 3 Package Contents One 1 HDMI 4x4 Matrix Switch 4K 60 One 1 12V 2A DC power adapter Three 3 Blades US UK and Euro One 1 Quick Reference Sheet One 1 HDMI Matrix IR Remote One 1 RS232 Terminal Blo...

Page 5: ...t Ports Four 4 HDMI Receptacle Control Push Button RS232 Telnet Web GUI IR ESD Protection Human body Model 8kV Air gap discharge 4kV Contact discharge Power Supply One 1 110 240V 12VDC 2 0A power supply with interchangeable blades Dimensions 10 63 4 33 x0 98 270 110 25 mm Weight 2 40lb 1090 g Chassis Material Metal Chassis Color Black Operating Temperature 0 ºC to 40 ºC 32 ºF to 104 ºF Storage Tem...

Page 6: ...cted and routed to HDMI 3 display 5 Output 4 Press the HDMI OUT 4 button repeatedly to switch to your desired source and the LED will illuminate to indicate which input source is being selected and routed to HDMI 4 display 6 Power The LED will illuminate when the power switch is turned on 5 2 Rear Panel No Name Description 1 Power Plug the 12VDC 2A power supply adapter into the unit and connect th...

Page 7: ...ayer a game console an A V Receiver a Cable or Satellite Receiver etc to the HDMI inputs on the unit Note that high quality premium 4K HDMI cables are recommended 3 Connect the HDMI output ports to Ultra High Definition displays such as an 4K TVs and projectors that support HDMI connectivity Note that high quality premium 4K HDMI cables are recommended 4 For power plug in the unit power jack first...

Page 8: ...e LAN port on the matrix switch to an unused active port on the Ethernet Switch or Router 2 Get the IP Address by CMD exe Enter ping matrix into CMD windows as follows 3 Enter the IP Address into any web browser as follows 4 Enter Username and Password to login the Web GUI Default Username is admin Default Password is admin ...

Page 9: ...te Setting tab the User can set any input port to any output port one by one or set any input port to one or more output ports In the EDID Management interface the User can load a Default EDID to any input port and you can also learn the EDID from any output port to any input port ...

Page 10: ... Matrix Switch 4K 60 Installation Guide Muxlab Inc 2020 9 In the IP Settings tab you can set the IP Settings such as Enable or disable DHCP Host IP Net Mask Gateway NOTE Default IP setting is with DHCP enabled ...

Page 11: ...uter Get the Matrix switch IP address through one of the below two methods 1 Run cmd exe from the PC then input ping matrix 2 Use the UART PORT to send the get current IP address command The TCP port is 8080 2 Command Description 2 1 Command Format in Hex Header Code 2bytes Command Type 1byte Length 2byte Parameters Checksum 1byte 0xCC 0xDD N Data 0 data N 1 The commands are in Hex 2 1 1 Header co...

Page 12: ...DID Head Code 2bytes Command type 1byte Length 2byte parameters Checksum 1byte 0xCC 0xDD 0x01 0x00 0x03 0x05 Data 1 Data 2 0xXX Parameter description Data 0 0x05 sub command used for selecting fixed EDID Data 1 select EDID index which is the matrix switch default method Refer to the below table DATA 1 index EDID type 0 4KX2KP60_HDPCM_HDR 1 4KX2KP60_HDPCM 2 4KX2KP60_dolby_DTS5 1_HDR 3 4KX2KP60_dolb...

Page 13: ...his command is invalid Head Code 2bytes Command type 1byte Length 2byte parameters Checksum 1byte 0xCC 0xDD 0x01 0x00 0x03 0x04 Data 1 Data 2 0xXX Parameter description 0x04 sub command for EDID manage indicates that this command is used to learn the EDID from the sink device Data 1 Select the output HDMI port which matrix switch gets the EDID DATA 1 Sink 0 HDMI OUT 1 1 HDMI OUT 2 2 HDMI OUT 3 3 H...

Page 14: ...I input port Data 1 HDMI input port index 0 Input 1 1 Input 2 2 Input 3 3 Input 4 Data 2 HDMI output port index 0 Output 1 1 Output 2 2 Output 3 3 Output 4 Example Connecting HDMI output port 3 to HDMI input port 2 Command is 0xCC 0xDD 0x02 0x00 0x03 0x01 0x01 0x02 0x12 3 2 2 Map all the output ports to an input port Head Code 2bytes Command type 1byte Length 2byte parameters Checksum 1byte 0xCC 0...

Page 15: ...ata 3 indicates HDMI output 3 links to which HDMI input port Data 4 indicates HDMI output 4 links to which HDMI input port index port 0 Input 1 1 Input 2 2 Input 3 3 Input 4 3 3 Network configuration 0x05 Network setting has three sub commands the first data parameter is used for the sub command The sub command is defined as shown below Network setting Sub command code Set static IP address 0x01 R...

Page 16: ...0x00 0x02 0x02 0x00 0x14 Matrix responds to PC Head Code 2bytes Command type 1byte Length 2byte parameters Checksum 1byte 0xCC 0xDD 0x05 0x00 0x0E 0x02 DATA 1 DATA 13 0x14 0x02 sub command reading matrix switch current IP address Data 1 Data 4 these four bytes indicates the setting IP address example 192 168 31 113 Data 1 0xC0 192 Data 2 0xA8 168 Data 3 0x1F 31 Data 4 0x71 113 Data 5 Data 8 these ...

Page 17: ...ype 1byte Length 2byte parameters Checksum 1byte 0xCC 0xDD 0x05 0x00 0x02 0x04 Data 1 0xXX Parameter Area description 0x04 sub comand setting DHCP static IP mode Data 1 indicates DHCP mode static IP mode 1 DHCP mode 0 static IP mode Example setting matrix switch to static IP mode Command is 0xCC 0xDD 0x05 0x00 0x02 0x04 0x00 0x12 ...

Page 18: ...t not limited to special incidental consequential or other damages No part of this document may be reproduced or transmitted in any form by any means electronic or mechanical including photocopying recording or information recording and retrieval systems without the express written permission of the manufacturer All brand names and product names used in this document are trademarks or registered t...

Reviews: