4 Parts Replacement
VJ-1604
Maintenance Manual
Rev.-00
4-82
(2) Replacing Flushing Tray L
1. Open the maintenance cover L.
2. Lift up the flushing frame hook.
3. Remove the flushing frame.
4. Detach the flushing tray by pushing the flushing tray from behind the flushing frame.
5. Replace the flushing tray.
6. To reassemble the unit, reverse the removal procedure.
4.6.12 Replacing Flushing Absorber
CAUTION
When replacing the flushing absorber, wear rubber gloves.
1. Remove the flushing frame.
"4.6.11 Replacing Flushing Tray" p.4-80
No.
Part name
1
Flushing tray
2
Flushing frame
3
Flushing frame hook
1
2
3